EVALUATION OF NEUTRON SCATTERING CORRECTION USING THE SEMI-EMPIRICAL METHOD AND THE SHADOW-CONE METHOD FOR THE NEUTRON FIELD OF THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE. Issue 1 (19th October 2017)
- Record Type:
- Journal Article
- Title:
- EVALUATION OF NEUTRON SCATTERING CORRECTION USING THE SEMI-EMPIRICAL METHOD AND THE SHADOW-CONE METHOD FOR THE NEUTRON FIELD OF THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE. Issue 1 (19th October 2017)
- Main Title:
- EVALUATION OF NEUTRON SCATTERING CORRECTION USING THE SEMI-EMPIRICAL METHOD AND THE SHADOW-CONE METHOD FOR THE NEUTRON FIELD OF THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE
- Authors:
- Lee, Seung Kyu
Kim, Sang In
Lee, Jungil
Chang, Insu
Kim, Jang-Lyul
Kim, Hyoungtaek
Kim, Min Chae
Kim, Bong-Hwan - Abstract:
- Abstract: When neutron survey metres are calibrated in neutron fields, the results for room- and air-scattered neutrons vary according to the distance from the source and the size, shape and construction of the neutron calibration room. ISO 8529-2 recommends four approaches for correcting these effects: the shadow-cone method, semi-empirical method, generalised fit method and reduced-fitting method. In this study, neutron scattering effects are evaluated and compared using the shadow-cone and semi-empirical methods for the neutron field of the Korea Atomic Energy Research Institute (KAERI). The neutron field is constructed using a 252 Cf neutron source positioned in the centre of the neutron calibration room. To compare the neutron scattering effects using the two correction methods, measurements and simulations are performed using respectively KAERI's Bonner sphere spectrometer (BBS) and Monte Carlo N-Particle code at twenty different positions. Neutron spectra are measured by a europium-activated lithium iodide [ 6 LiI(Eu)] scintillator in combination with the BBS. The calibration factors obtained using each methods show good agreement within 1.1%.
- Is Part Of:
- Radiation protection dosimetry. Volume 180:Issue 1/4(2018)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 180:Issue 1/4(2018)
- Issue Display:
- Volume 180, Issue 1/4 (2018)
- Year:
- 2018
- Volume:
- 180
- Issue:
- 1/4
- Issue Sort Value:
- 2018-0180-NaN-0000
- Page Start:
- 46
- Page End:
- 50
- Publication Date:
- 2017-10-19
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncx219 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12177.xml