Trends in Bone Marrow Sampling and Core Biopsy Specimen Adequacy in the United States and Canada: A Multicenter Study. Issue 5 (20th July 2018)
- Record Type:
- Journal Article
- Title:
- Trends in Bone Marrow Sampling and Core Biopsy Specimen Adequacy in the United States and Canada: A Multicenter Study. Issue 5 (20th July 2018)
- Main Title:
- Trends in Bone Marrow Sampling and Core Biopsy Specimen Adequacy in the United States and Canada
- Authors:
- Merzianu, Mihai
Groman, Adrienne
Hutson, Alan
Cotta, Claudiu
Brynes, Russell K
Orazi, Attilio
Reddy, Vishnu
Teruya-Feldstein, Julie
Amre, Ramila
Balasubramanian, Manjula
Brandao, Guilherme
Cherian, Sindhu
Courville, Elizabeth
Czuchlewski, David
Fan, Guang
Grier, David
Hoehn, Daniela
Inamdar, Kedar V
Juskevicius, Ridas
Kaur, Prabhjot
Lazarchick, John
Lewis, Michael R
Miles, Rodney R
Myers, Jerome B
Nasr, Michel R
Qureishi, Hina N
Olteanu, Horatiu
Robu, Valentin G
Salaru, Gratian
Vajpayee, Neerja
Vos, Jeffrey
Zhang, Ling
Zhang, Shanxiang
Aye, Le
Brega, Elisa
Coad, James E
Grantham, John
Ivelja, Sinisa
McKenna, Robert
Sultan, Kieran
Wilding, Gregory
Hutchison, Robert
Peterson, LoAnn
Cheney, Richard T
… (more) - Abstract:
- Abstract: Objectives: To assess bone marrow (BM) sampling in academic medical centers. Methods: Data from 6, 374 BM samples obtained in 32 centers in 2001 and 2011, including core length (CL), were analyzed. Results: BM included a biopsy (BMB; 93%) specimen, aspirate (BMA; 92%) specimen, or both (83%). The median (SD) CL was 12 (8.5) mm, and evaluable marrow was 9 (7.6) mm. Tissue contraction due to processing was 15%. BMB specimens were longer in adults younger than 60 years, men, and bilateral, staging, and baseline samples. Only 4% of BMB and 2% of BMB/BMA samples were deemed inadequate for diagnosis. BM for plasma cell dyscrasias, nonphysician operators, and ancillary studies usage increased, while bilateral sampling decreased over the decade. BM-related quality assurance programs are infrequent. Conclusions: CL is shorter than recommended and varies with patient age and sex, clinical circumstances, and center experience. While pathologists render diagnoses on most cases irrespective of CL, BMB yield improvement is desirable.
- Is Part Of:
- American journal of clinical pathology. Volume 150:Issue 5(2018)
- Journal:
- American journal of clinical pathology
- Issue:
- Volume 150:Issue 5(2018)
- Issue Display:
- Volume 150, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 150
- Issue:
- 5
- Issue Sort Value:
- 2018-0150-0005-0000
- Page Start:
- 393
- Page End:
- 405
- Publication Date:
- 2018-07-20
- Subjects:
- Bone marrow biopsy -- Bone marrow biopsy indications -- Core biopsy length -- Bone marrow adequacy -- Bone marrow quality
Diagnosis, Laboratory -- Periodicals
Pathology -- Periodicals
616.07 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
http://ajcp.oxfordjournals.org/ ↗ - DOI:
- 10.1093/ajcp/aqy066 ↗
- Languages:
- English
- ISSNs:
- 0002-9173
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0824.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12182.xml