Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck. (11th November 2019)
- Record Type:
- Journal Article
- Title:
- Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck. (11th November 2019)
- Main Title:
- Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck
- Authors:
- Sommer, Bettina B.
Weisenhorn, Martin
Ernst, Markus J.
Meichtry, André
Rast, Fabian M.
Kleger, Dominik
Schmid, Philipp
Lünenburger, Lars
Bauer, Christoph M. - Abstract:
- Abstract: The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR to measure six degrees of freedom in a clinical setting. The aim of this study was to assess the validity and reliability of this system. The developed prototype consists of two infrared-emitting lighthouses and sensors, mounted on the participant's helmet and trunk belt, to detect the orientation of the head and trunk. The system was evaluated by means of an infrared light-reflecting marker tracking system. Twenty healthy participants, equipped with these sensors and markers, performed thirteen neck movement tasks. Linear and angular movements were measured. These tasks were repeated after six to eight days to assess test-retest reliability. Concurrent validity was assessed by the root mean square error, and reliability with generalizability theory. With an average root mean square error between 1.2 and 2.0° in angular and 0.4–0.5 cm in linear movements, the prototype was shown to precisely track these movements. Reliability of the prototype and the reference system was comparable for all tasks. A high contribution of participant's variability to the observed variance was generally detected, with the exception of joint repositioning error and upperAbstract: The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR to measure six degrees of freedom in a clinical setting. The aim of this study was to assess the validity and reliability of this system. The developed prototype consists of two infrared-emitting lighthouses and sensors, mounted on the participant's helmet and trunk belt, to detect the orientation of the head and trunk. The system was evaluated by means of an infrared light-reflecting marker tracking system. Twenty healthy participants, equipped with these sensors and markers, performed thirteen neck movement tasks. Linear and angular movements were measured. These tasks were repeated after six to eight days to assess test-retest reliability. Concurrent validity was assessed by the root mean square error, and reliability with generalizability theory. With an average root mean square error between 1.2 and 2.0° in angular and 0.4–0.5 cm in linear movements, the prototype was shown to precisely track these movements. Reliability of the prototype and the reference system was comparable for all tasks. A high contribution of participant's variability to the observed variance was generally detected, with the exception of joint repositioning error and upper cervical flexion. The reliability was task-specific and did not differ between the systems. The prototype system was shown to be valid, although the reliability of the repositioning and upper cervical flexion tests needs to be reconsidered. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 96(2019)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 96(2019)
- Issue Display:
- Volume 96, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 96
- Issue:
- 2019
- Issue Sort Value:
- 2019-0096-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11-11
- Subjects:
- Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2019.109340 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12170.xml