Medical air in healthcare institutions: A chemical and biological study. (15th December 2019)
- Record Type:
- Journal Article
- Title:
- Medical air in healthcare institutions: A chemical and biological study. (15th December 2019)
- Main Title:
- Medical air in healthcare institutions: A chemical and biological study
- Authors:
- Groulx, Nicolas
Movahhedinia, Hosna
Edwards, Paul
Qureshi, Faisal
Yip, Lily
Katz, Kevin
Mubareka, Samira
Evans, Greg - Abstract:
- Abstract: A significant proportion of hospitalized patients are dependent on medical air. Medical air is commonly produced on-site from filtered and compressed external air before delivery to patients through centralized piping. Little is known about how outside ambient air composition can affect medical air quality. This study examined how chemical and microbial content of medical air varied at the delivery ports as a function of ambient air. The chemical composition was monitored near the outdoor air intake and at the indoor outlet in a patient room of a healthcare center. The microbial content was determined twice weekly using a custom-made impaction device designed for pressurized systems. Results revealed some chemical gases are not well filtered by the medical air system; the average concentrations of CO and CO2 in this medical air (160 ppb and 442 ppm) were similar to outdoor concentrations, indicating that these gases pass freely to bedside outlets. NOx and O3 are only 40% removed yielding average concentrations of 16 and 10 ppb in this medical air. Trace metals could also be detected. Bacteria were detected, but at concentrations significantly lower than 1 colony forming unit (CFU) per m 3 of medical air sampled; these consisted predominantly of non-pathogenic bacteria. This study highlights the impact of changes in outdoor air quality on the composition of medical air delivered to patients, and the importance of monitoring and regulating the quality of medical air.Abstract: A significant proportion of hospitalized patients are dependent on medical air. Medical air is commonly produced on-site from filtered and compressed external air before delivery to patients through centralized piping. Little is known about how outside ambient air composition can affect medical air quality. This study examined how chemical and microbial content of medical air varied at the delivery ports as a function of ambient air. The chemical composition was monitored near the outdoor air intake and at the indoor outlet in a patient room of a healthcare center. The microbial content was determined twice weekly using a custom-made impaction device designed for pressurized systems. Results revealed some chemical gases are not well filtered by the medical air system; the average concentrations of CO and CO2 in this medical air (160 ppb and 442 ppm) were similar to outdoor concentrations, indicating that these gases pass freely to bedside outlets. NOx and O3 are only 40% removed yielding average concentrations of 16 and 10 ppb in this medical air. Trace metals could also be detected. Bacteria were detected, but at concentrations significantly lower than 1 colony forming unit (CFU) per m 3 of medical air sampled; these consisted predominantly of non-pathogenic bacteria. This study highlights the impact of changes in outdoor air quality on the composition of medical air delivered to patients, and the importance of monitoring and regulating the quality of medical air. Highlights: Chemical and biological contamination in hospital medical air was measured. The medical air quality reflected that of the outdoor air used to generate it. CO and CO2 tracked outdoor air concentrations while O3 and NOx were partially removed. Concentrations of particulate were much lower than in outside ambient air. … (more)
- Is Part Of:
- Atmospheric environment. Volume 219(2019)
- Journal:
- Atmospheric environment
- Issue:
- Volume 219(2019)
- Issue Display:
- Volume 219, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 219
- Issue:
- 2019
- Issue Sort Value:
- 2019-0219-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12-15
- Subjects:
- Medical air -- Air pollution -- Microbes -- Chemical gases -- Hospitals -- Bioburden
Air -- Pollution -- Periodicals
Air -- Pollution -- Meteorological aspects -- Periodicals
551.51 - Journal URLs:
- http://www.sciencedirect.com/web-editions/journal/13522310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.atmosenv.2019.117031 ↗
- Languages:
- English
- ISSNs:
- 1352-2310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1767.120000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12152.xml