Evaluating the feasibility of creatine‐weighted CEST MRI in human brain at 7 T using a Z‐spectral fitting approach. (14th October 2019)
- Record Type:
- Journal Article
- Title:
- Evaluating the feasibility of creatine‐weighted CEST MRI in human brain at 7 T using a Z‐spectral fitting approach. (14th October 2019)
- Main Title:
- Evaluating the feasibility of creatine‐weighted CEST MRI in human brain at 7 T using a Z‐spectral fitting approach
- Authors:
- Singh, Anup
Debnath, Ayan
Cai, Kejia
Bagga, Puneet
Haris, Mohammad
Hariharan, Hari
Reddy, Ravinder - Abstract:
- Abstract : The current study aims to evaluate the feasibility of creatine (Cr) chemical exchange saturation transfer (CEST)‐weighted MRI at 7 T in the human brain by optimizing the saturation pulse parameters and computing contrast using a Z‐spectral fitting approach. The Cr‐weighted (Cr‐w) CEST contrast was computed from phantoms data. Simulations were carried out to obtain the optimum saturation parameters for Cr‐w CEST with lower contribution from other brain metabolites. CEST‐w images were acquired from the brains of four human subjects at different saturation parameters. The Cr‐w CEST contrast was computed using both asymmetry analysis and Z‐spectra fitting approaches (models 1 and 2, respectively) based on Lorentzian functions. For broad magnetization transfer (MT) effect, Gaussian and Super‐Lorentzian line shapes were also evaluated. In the phantom study, the Cr‐w CEST contrast showed a linear dependence on concentration in physiological range and a nonlinear dependence on saturation parameters. The in vivo Cr‐w CEST map generated using asymmetry analysis from the brain represents mixed contrast with contribution from other metabolites as well and relayed nuclear Overhauser effect (rNOE). Simulations provided an estimate for the optimum range of saturation parameters to be used for acquiring brain CEST data. The optimum saturation parameters for Cr‐w CEST to be used for brain data were around B1rms = 1.45 μT and duration = 2 seconds. The Z‐spectral fitting approachAbstract : The current study aims to evaluate the feasibility of creatine (Cr) chemical exchange saturation transfer (CEST)‐weighted MRI at 7 T in the human brain by optimizing the saturation pulse parameters and computing contrast using a Z‐spectral fitting approach. The Cr‐weighted (Cr‐w) CEST contrast was computed from phantoms data. Simulations were carried out to obtain the optimum saturation parameters for Cr‐w CEST with lower contribution from other brain metabolites. CEST‐w images were acquired from the brains of four human subjects at different saturation parameters. The Cr‐w CEST contrast was computed using both asymmetry analysis and Z‐spectra fitting approaches (models 1 and 2, respectively) based on Lorentzian functions. For broad magnetization transfer (MT) effect, Gaussian and Super‐Lorentzian line shapes were also evaluated. In the phantom study, the Cr‐w CEST contrast showed a linear dependence on concentration in physiological range and a nonlinear dependence on saturation parameters. The in vivo Cr‐w CEST map generated using asymmetry analysis from the brain represents mixed contrast with contribution from other metabolites as well and relayed nuclear Overhauser effect (rNOE). Simulations provided an estimate for the optimum range of saturation parameters to be used for acquiring brain CEST data. The optimum saturation parameters for Cr‐w CEST to be used for brain data were around B1rms = 1.45 μT and duration = 2 seconds. The Z‐spectral fitting approach enabled computation of individual components. This also resulted in mitigating the contribution from MT and rNOE to Cr‐w CEST contrast, which is a major source of underestimation in asymmetry analysis. The proposed modified z‐spectra fitting approach (model 2) is more stable to noise compared with model 1. Cr‐w CEST contrast obtained using fitting was 6.98 ± 0.31% in gray matter and 5.45 ± 0.16% in white matter. Optimal saturation parameters reduced the contribution from other CEST effects to Cr‐w CEST contrast, and the proposed Z‐spectral fitting approach enabled computation of individual components in Z‐spectra of the brain. Therefore, it is feasible to compute Cr‐w CEST contrast with a lower contribution from other CEST and rNOE. Abstract : Optimal saturation parameters reduced contribution from other CEST effects to Cr‐weighted CEST contrast in human brain at 7 T and a proposed Z‐spectral fitting approach enabled computation of individual components in Z‐spectra. The optimum saturation parameters for Cr‐w CEST to be used for brain data were around B1rms = 1.45μT and duration of 2 seconds. … (more)
- Is Part Of:
- NMR in biomedicine. Volume 32:Number 12(2019)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 32:Number 12(2019)
- Issue Display:
- Volume 32, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 32
- Issue:
- 12
- Issue Sort Value:
- 2019-0032-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-10-14
- Subjects:
- chemical exchange saturation transfer -- creatine -- creatine‐weighted chemical exchange saturation transfer -- Lorentzian -- magnetic resonance imaging -- Z‐spectra
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.4176 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12148.xml