Machine perfusion and long-term kidney transplant recipient outcomes across allograft risk strata. Issue 7 (20th February 2018)
- Record Type:
- Journal Article
- Title:
- Machine perfusion and long-term kidney transplant recipient outcomes across allograft risk strata. Issue 7 (20th February 2018)
- Main Title:
- Machine perfusion and long-term kidney transplant recipient outcomes across allograft risk strata
- Authors:
- Sandal, Shaifali
Luo, Xun
Massie, Allan B
Paraskevas, Steven
Cantarovich, Marcelo
Segev, Dorry L - Abstract:
- ABSTRACT: Background: The use of machine perfusion (MP) in kidney transplantation lowers delayed graft function (DGF) and improves 1-year graft survival in some, but not all, grafts. These associations have not been explored in grafts stratified by the Kidney Donor Profile index (KDPI). Methods: We analyzed 78 207 deceased-donor recipients using the Scientific Registry of Transplant Recipients data from 2006 to 2013. The cohort was stratified using the standard criteria donor/expanded criteria donor (ECD)/donation after cardiac death (DCD)/donation after brain death (DBD) classification and the KDPI scores. In each subgroup, MP use was compared with cold storage. Results: The overall DGF rate was 25.4% and MP use was associated with significantly lower DGF in all but the ECD–DCD donor subgroup. Using the donor source classification, the use of MP did not decrease death-censored graft failure (DCGF), except in the ECD–DCD subgroup from 0 to 1 year {adjusted hazard ratio [aHR] 0.56 [95% confidence interval (CI) 0.32–0.98]}. In the ECD–DBD subgroup, higher DCGF from 1 to 5 years was noted [aHR 1.15 (95% CI 1.01–1.31)]. Also, MP did not lower all-cause graft failure except in the ECD–DCD subgroup from 0 to 1 year [aHR = 0.59 (95% CI 0.38–0.91)]. Using the KDPI classification, MP did not lower DCGF or all-cause graft failure, but in the ≤70 subgroup, higher DCGF [aHR 1.16 (95% CI 1.05–1.27)] and higher all-cause graft failure [aHR 1.10 (95% CI 1.02–1.18)] was noted. Lastly, MPABSTRACT: Background: The use of machine perfusion (MP) in kidney transplantation lowers delayed graft function (DGF) and improves 1-year graft survival in some, but not all, grafts. These associations have not been explored in grafts stratified by the Kidney Donor Profile index (KDPI). Methods: We analyzed 78 207 deceased-donor recipients using the Scientific Registry of Transplant Recipients data from 2006 to 2013. The cohort was stratified using the standard criteria donor/expanded criteria donor (ECD)/donation after cardiac death (DCD)/donation after brain death (DBD) classification and the KDPI scores. In each subgroup, MP use was compared with cold storage. Results: The overall DGF rate was 25.4% and MP use was associated with significantly lower DGF in all but the ECD–DCD donor subgroup. Using the donor source classification, the use of MP did not decrease death-censored graft failure (DCGF), except in the ECD–DCD subgroup from 0 to 1 year {adjusted hazard ratio [aHR] 0.56 [95% confidence interval (CI) 0.32–0.98]}. In the ECD–DBD subgroup, higher DCGF from 1 to 5 years was noted [aHR 1.15 (95% CI 1.01–1.31)]. Also, MP did not lower all-cause graft failure except in the ECD–DCD subgroup from 0 to 1 year [aHR = 0.59 (95% CI 0.38–0.91)]. Using the KDPI classification, MP did not lower DCGF or all-cause graft failure, but in the ≤70 subgroup, higher DCGF [aHR 1.16 (95% CI 1.05–1.27)] and higher all-cause graft failure [aHR 1.10 (95% CI 1.02–1.18)] was noted. Lastly, MP was not associated with mortality in any subgroup. Conclusions: Overall, MP did not lower DCGF. Neither classification better risk-stratified kidneys that have superior graft survival with MP. We question their widespread use in all allografts as an ideal approach to organ preservation. … (more)
- Is Part Of:
- Nephrology dialysis transplantation. Volume 33:Issue 7(2018)
- Journal:
- Nephrology dialysis transplantation
- Issue:
- Volume 33:Issue 7(2018)
- Issue Display:
- Volume 33, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 33
- Issue:
- 7
- Issue Sort Value:
- 2018-0033-0007-0000
- Page Start:
- 1251
- Page End:
- 1259
- Publication Date:
- 2018-02-20
- Subjects:
- delayed graft function -- graft outcomes -- kidney transplantation -- machine perfusion -- organ preservation
Nephrology -- Periodicals
Hemodialysis -- Periodicals
Kidneys -- Transplantation -- Periodicals
Hemodialysis
Kidneys -- Transplantation
Nephrology
Periodicals
616.61 - Journal URLs:
- http://ndt.oxfordjournals.org/ ↗
http://www.oup.co.uk/ndt/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0931-0509;screen=info;ECOIP ↗ - DOI:
- 10.1093/ndt/gfy010 ↗
- Languages:
- English
- ISSNs:
- 0931-0509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.685300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12127.xml