Feasibility of transcatheter aortic valve implantation in patients with coronary heights ≤7 mm: insights from the transcatheter aortic valve implantation Karlsruhe (TAVIK) registry. (2nd April 2018)
- Record Type:
- Journal Article
- Title:
- Feasibility of transcatheter aortic valve implantation in patients with coronary heights ≤7 mm: insights from the transcatheter aortic valve implantation Karlsruhe (TAVIK) registry. (2nd April 2018)
- Main Title:
- Feasibility of transcatheter aortic valve implantation in patients with coronary heights ≤7 mm: insights from the transcatheter aortic valve implantation Karlsruhe (TAVIK) registry
- Authors:
- Conzelmann, Lars O
Würth, Alexander
Schymik, Gerhard
Schröfel, Holger
Anusic, Tonic
Temme, Stefanie
Tzamalis, Panagiotis
Gerhardus, Jan
Mukherjee, Chirojit
Gonska, Bernd-Dieter
Schmitt, Claus
Mehlhorn, Uwe - Abstract:
- Abstract: OBJECTIVES: Transcatheter aortic valve implantation (TAVI) in patients with low coronary heights is generally denied but is not impossible. Information about these high-risk procedures is sparse. METHODS: Since May 2008, data of more than 3000 patients who had TAVI were prospectively collected in the institutional TAVI Karlsruhe registry. Characteristics, peri- and postoperative outcome of patients with low coronary heights of ≤7 mm were analysed according to the Valve Academic Research Consortium-2. RESULTS: Eighty-six patients with an average coronary height of 6.4 ± 1.1 mm (mean age 81.0 ± 5.3 years, logistic EuroSCORE I 19.6 ± 13.3%) were treated. TAVI was performed in 72 transfemoral (83.7%) and 14 transapical (16.3%) cases using 44 CoreValve/Evolut R (51.2%), 21 Sapien XT/S3 (24.4%), 14 ACURATE (16.3%), 5 Lotus (5.8%) and 2 Portico (2.3%) prostheses. Ten procedures were valve-in-valve (VinV) TAVI (VinV, 11.6%). The 72-h, 30-day, 1-year and follow-up (3.0 ± 1.6 years) mortality rates were 2.3%, 8.0%, 10.5% and 26.7%, respectively. Within 30 days, 4 cardiac deaths and 3 non-cardiac deaths occurred (4.7% and 3.5%). Three coronary obstructions (3.5%) occurred—2 during VinV TAVI. One patient was connected to extracorporeal circulation that could not be weaned later due to an unsuccessful percutaneous coronary intervention. Another patient, the only conversion (1.2%), required delayed surgical valve replacement. The third patient died of right heart failure afterAbstract: OBJECTIVES: Transcatheter aortic valve implantation (TAVI) in patients with low coronary heights is generally denied but is not impossible. Information about these high-risk procedures is sparse. METHODS: Since May 2008, data of more than 3000 patients who had TAVI were prospectively collected in the institutional TAVI Karlsruhe registry. Characteristics, peri- and postoperative outcome of patients with low coronary heights of ≤7 mm were analysed according to the Valve Academic Research Consortium-2. RESULTS: Eighty-six patients with an average coronary height of 6.4 ± 1.1 mm (mean age 81.0 ± 5.3 years, logistic EuroSCORE I 19.6 ± 13.3%) were treated. TAVI was performed in 72 transfemoral (83.7%) and 14 transapical (16.3%) cases using 44 CoreValve/Evolut R (51.2%), 21 Sapien XT/S3 (24.4%), 14 ACURATE (16.3%), 5 Lotus (5.8%) and 2 Portico (2.3%) prostheses. Ten procedures were valve-in-valve (VinV) TAVI (VinV, 11.6%). The 72-h, 30-day, 1-year and follow-up (3.0 ± 1.6 years) mortality rates were 2.3%, 8.0%, 10.5% and 26.7%, respectively. Within 30 days, 4 cardiac deaths and 3 non-cardiac deaths occurred (4.7% and 3.5%). Three coronary obstructions (3.5%) occurred—2 during VinV TAVI. One patient was connected to extracorporeal circulation that could not be weaned later due to an unsuccessful percutaneous coronary intervention. Another patient, the only conversion (1.2%), required delayed surgical valve replacement. The third patient died of right heart failure after aortic dissection. The procedural success rate was 95.3%. VinV procedures were associated with increased follow-up deaths ( P < 0.001; hazard ratio 7.96). CONCLUSIONS: Coronary-related complications in TAVI procedures in patients with coronary heights ≤7 mm occurred less frequently, but once they occurred, they were serious. These TAVI procedures are feasible, with a high procedural success rate, but meticulous preoperative planning should be mandatory. In VinV procedures, the follow-up mortality rate is increased; therefore, we do not recommend these procedures. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 54:Number 4(2018)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 54:Number 4(2018)
- Issue Display:
- Volume 54, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 54
- Issue:
- 4
- Issue Sort Value:
- 2018-0054-0004-0000
- Page Start:
- 752
- Page End:
- 761
- Publication Date:
- 2018-04-02
- Subjects:
- Transcatheter aortic valve implantation -- Mortality -- Complication -- Coronary obstruction -- High risk
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezy130 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12141.xml