Evaluation of umbilical cord entanglement as a predictive factor of adverse pregnancy outcomes: A meta-analysis. (December 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of umbilical cord entanglement as a predictive factor of adverse pregnancy outcomes: A meta-analysis. (December 2019)
- Main Title:
- Evaluation of umbilical cord entanglement as a predictive factor of adverse pregnancy outcomes: A meta-analysis
- Authors:
- Pergialiotis, Vasilios
Fanaki, Maria
Bellos, Ioannis
Tzortzis, Andrianos
Loutradis, Dimitrios
Daskalakis, Georgios - Abstract:
- Abstract: The purpose of the present systematic review is to summarize current data concerning the impact of umbilical cord entanglement on adverse pregnancy outcomes. We used the Medline, Scopus, EMBASE, Cochrane Central Register of Controlled Trials CENTRAL and Google Scholar databases. We selected all observational (both prospective and retrospective) studies for inclusion. Meta-analysis of the risk ratios (RR) was performed with RevMan 5.3 software. Univariate meta-regression and leave-one-out meta-analysis was performed with Open Meta-Analyst statistical software. Trial sequential analysis was performed with the TSA software. Overall, twenty studies were included in the present study with 267, 233 pregnant women (50.103 with cord entanglement and 217, 130 controls). An increased risk of neonatal Apgar score <7 at the first minute of life was observed among cases with cord entanglement (RR = 1.75, 95% CI 1.46, 2.11). Fetal distress was significantly higher in the entanglement group (RR 1.50, 95% CI 1.33, 1.69). The incidence of fetal pH < 7.1 was also significantly higher in the entanglement group (RR 1.73, 95% CI 1.48, 2.03). Adequate power was observed in all investigated outcomes of our primary analysis after evaluating the results of the TSA analysis. Prediction intervals designated that future studies were likely to report increased risk of low Apgar score at the first minute of life, increased risk of fetal distress as well as of observing a fetal pH < 7.1.Abstract: The purpose of the present systematic review is to summarize current data concerning the impact of umbilical cord entanglement on adverse pregnancy outcomes. We used the Medline, Scopus, EMBASE, Cochrane Central Register of Controlled Trials CENTRAL and Google Scholar databases. We selected all observational (both prospective and retrospective) studies for inclusion. Meta-analysis of the risk ratios (RR) was performed with RevMan 5.3 software. Univariate meta-regression and leave-one-out meta-analysis was performed with Open Meta-Analyst statistical software. Trial sequential analysis was performed with the TSA software. Overall, twenty studies were included in the present study with 267, 233 pregnant women (50.103 with cord entanglement and 217, 130 controls). An increased risk of neonatal Apgar score <7 at the first minute of life was observed among cases with cord entanglement (RR = 1.75, 95% CI 1.46, 2.11). Fetal distress was significantly higher in the entanglement group (RR 1.50, 95% CI 1.33, 1.69). The incidence of fetal pH < 7.1 was also significantly higher in the entanglement group (RR 1.73, 95% CI 1.48, 2.03). Adequate power was observed in all investigated outcomes of our primary analysis after evaluating the results of the TSA analysis. Prediction intervals designated that future studies were likely to report increased risk of low Apgar score at the first minute of life, increased risk of fetal distress as well as of observing a fetal pH < 7.1. Concluding, the findings of this systematic review suggest that there is sufficient evidence to support the involvement of cord entanglement to adverse neonatal perinatal outcomes. … (more)
- Is Part Of:
- European journal of obstetrics, gynecology, and reproductive biology. Volume 243(2019)
- Journal:
- European journal of obstetrics, gynecology, and reproductive biology
- Issue:
- Volume 243(2019)
- Issue Display:
- Volume 243, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 243
- Issue:
- 2019
- Issue Sort Value:
- 2019-0243-2019-0000
- Page Start:
- 150
- Page End:
- 157
- Publication Date:
- 2019-12
- Subjects:
- Cord entanglement -- Cord compression -- Adverse outcome -- Labor -- Delivery
Obstetrics -- Periodicals
Gynecology -- Periodicals
Reproductive health -- Periodicals
Gynecology -- Periodicals
Obstetrics -- Periodicals
Reproduction -- Periodicals
Obstétrique -- Périodiques
Gynécologie -- Périodiques
Reproduction -- Périodiques
Verloskunde
Gynaecologie
Voortplanting (biologie)
Gynecology
Obstetrics
Reproduction
Electronic journals
Periodicals
Electronic journals
618.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03012115 ↗
http://www.ingentaconnect.com/content/els/00282243 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03012115 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03012115 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejogrb.2019.10.038 ↗
- Languages:
- English
- ISSNs:
- 0301-2115
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.733000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12134.xml