Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder. (September 2019)
- Record Type:
- Journal Article
- Title:
- Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder. (September 2019)
- Main Title:
- Role of baseline 12‑lead ECG in predicting syncope caused by arrhythmia in patients investigated using an implantable loop recorder
- Authors:
- Sandgren, Emma
Rorsman, Cecilia
Edvardsson, Nils
Engdahl, Johan - Abstract:
- Abstract: Aim: To evaluate the role of baseline 12‑lead ECG in predicting the syncope mechanism during continuous monitoring using an implantable loop recorder (ILR). Methods: Consecutive patients with syncope implanted with an ILR were enrolled. Baseline 12‑lead ECG were related to ECG diagnosis derived from ILR tracings recorded at the time of syncope recurrence. Results: In total 300 patients with a mean age of 66 ± 16 years were included, 49% (146/300) received an ILR-guided diagnosis during follow-up. Patients with abnormal baseline ECG more frequently received an ILR-guided diagnosis compared to those with normal baseline ECG 59% vs. 44%, p = 0.018. For a diagnosis of arrhythmic syncope, the corresponding frequencies were 45% vs. 26%, p = 0.001. Patients with bifascicular block significantly more common received an ILR-guided diagnosis 76% (25/33) compared to those with normal baseline ECG 44% (90/205), p ≪ 0.001. In this subgroup, 96% (24/25) were diagnosed with arrhythmic syncope, 23 of which were due to bradyarrhythmia. Bifascicular block occurred almost exclusively among those ≥60 years (31/33). After logistic regression the adjusted OR for arrhythmic syncope was significant for bifascicular block 5.5 (95%CI 2.3–13.2), p ≪ 0.001. PPV for bifascicular block in predicting arrhythmic syncope was 73% and NPV 73%. Conclusion: A baseline 12‑lead ECG with bifascicular block was a strong predictor for syncope during follow-up, most often due to bradyarrhythmia causedAbstract: Aim: To evaluate the role of baseline 12‑lead ECG in predicting the syncope mechanism during continuous monitoring using an implantable loop recorder (ILR). Methods: Consecutive patients with syncope implanted with an ILR were enrolled. Baseline 12‑lead ECG were related to ECG diagnosis derived from ILR tracings recorded at the time of syncope recurrence. Results: In total 300 patients with a mean age of 66 ± 16 years were included, 49% (146/300) received an ILR-guided diagnosis during follow-up. Patients with abnormal baseline ECG more frequently received an ILR-guided diagnosis compared to those with normal baseline ECG 59% vs. 44%, p = 0.018. For a diagnosis of arrhythmic syncope, the corresponding frequencies were 45% vs. 26%, p = 0.001. Patients with bifascicular block significantly more common received an ILR-guided diagnosis 76% (25/33) compared to those with normal baseline ECG 44% (90/205), p ≪ 0.001. In this subgroup, 96% (24/25) were diagnosed with arrhythmic syncope, 23 of which were due to bradyarrhythmia. Bifascicular block occurred almost exclusively among those ≥60 years (31/33). After logistic regression the adjusted OR for arrhythmic syncope was significant for bifascicular block 5.5 (95%CI 2.3–13.2), p ≪ 0.001. PPV for bifascicular block in predicting arrhythmic syncope was 73% and NPV 73%. Conclusion: A baseline 12‑lead ECG with bifascicular block was a strong predictor for syncope during follow-up, most often due to bradyarrhythmia caused by intermittent complete heart block. No other ECG findings were associated with the ILR outcome. We find it reasonable to consider permanent pacing instead of an ILR for patients with bifascicular block and unexplained syncope. Highlights: Bifascicular block at baseline ECG was a strong predictor for syncope. Bifascicular block was found almost exclusively among those above 60 years of age. Rational to consider permanent pacing for patients with bifascicular block and syncope No other 12‑lead ECG findings were associated with the ILR outcome. … (more)
- Is Part Of:
- IJC heart & vasculature. Volume 24(2019)
- Journal:
- IJC heart & vasculature
- Issue:
- Volume 24(2019)
- Issue Display:
- Volume 24, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 24
- Issue:
- 2019
- Issue Sort Value:
- 2019-0024-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- Syncope -- Implantable loop recorder -- Arrhythmia -- Bifascicular block
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular system -- Pathophysiology -- Periodicals
616.1005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23529067/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ijcha.2019.100386 ↗
- Languages:
- English
- ISSNs:
- 2352-9067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12135.xml