Apical stability of implants with progressive thread design in vitro, based on clinicians with different levels of experience. Issue 11 (1st July 2019)
- Record Type:
- Journal Article
- Title:
- Apical stability of implants with progressive thread design in vitro, based on clinicians with different levels of experience. Issue 11 (1st July 2019)
- Main Title:
- Apical stability of implants with progressive thread design in vitro, based on clinicians with different levels of experience
- Authors:
- Romanos, Georgios E.
Kuyunov, Osnat
Sacks, Danielle
Calvo‐Guirado, Jose Luis
Delgado‐Ruiz, Rafael - Abstract:
- Abstract: Background: The implant design and the surgical technique are important parameters that can be modified to improve the implant primary stability. The aim of this study was to evaluate the role of the apical part of an implant on the implant stability of implants placed in Type II dense bone by novice and experienced clinicians. Methods: Implants with a progressive thread design (3.5 mm diameter, 11 mm length) were used. A total of 80 osteotomies were prepared in dense bone samples (quality Type II) by two clinicians with different levels of experience (novice and experienced) under the same surgical protocol. Two experimental groups were prepared. In the test group (apical stability), 40 implants were inserted with only 3 mm of the apical portion of the implant within the bone and without lateral contact between the residual implant length and the osteotomy walls. In the control group (full implant stability), 40 implants were inserted with full contact between the osteotomy walls and the implant surface. The stability of both groups (test and control) was evaluated using a resonance frequency analysis (RFA) (implant stability quotient [ISQ] values). Statistical comparisons between the groups were performed using the Kruskal‐Wallis test with Dunn post‐test for multiple comparisons. Results: The results did not show statistically significant differences ( P > 0.05) in terms of primary stability between implants placed by novice or experienced clinicians in denseAbstract: Background: The implant design and the surgical technique are important parameters that can be modified to improve the implant primary stability. The aim of this study was to evaluate the role of the apical part of an implant on the implant stability of implants placed in Type II dense bone by novice and experienced clinicians. Methods: Implants with a progressive thread design (3.5 mm diameter, 11 mm length) were used. A total of 80 osteotomies were prepared in dense bone samples (quality Type II) by two clinicians with different levels of experience (novice and experienced) under the same surgical protocol. Two experimental groups were prepared. In the test group (apical stability), 40 implants were inserted with only 3 mm of the apical portion of the implant within the bone and without lateral contact between the residual implant length and the osteotomy walls. In the control group (full implant stability), 40 implants were inserted with full contact between the osteotomy walls and the implant surface. The stability of both groups (test and control) was evaluated using a resonance frequency analysis (RFA) (implant stability quotient [ISQ] values). Statistical comparisons between the groups were performed using the Kruskal‐Wallis test with Dunn post‐test for multiple comparisons. Results: The results did not show statistically significant differences ( P > 0.05) in terms of primary stability between implants placed by novice or experienced clinicians in dense bone. The control group showed significantly higher ISQ values compared with the test group ( P < 0.001). The apical implant stability contributed to ≈ 30% and 43% of the entire implant stability for novice and experienced clinicians, respectively. Conclusions: The apical portion of an implant plays a fundamental role in the entire implant stability and is independent on the clinician's experience. However, precise implant site preparation to guarantee apical implant anchorage is recommended. … (more)
- Is Part Of:
- Journal of periodontology. Volume 90:Issue 11(2019)
- Journal:
- Journal of periodontology
- Issue:
- Volume 90:Issue 11(2019)
- Issue Display:
- Volume 90, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 90
- Issue:
- 11
- Issue Sort Value:
- 2019-0090-0011-0000
- Page Start:
- 1320
- Page End:
- 1324
- Publication Date:
- 2019-07-01
- Subjects:
- design -- implant stability -- stability
Periodontics -- Periodicals
617.632 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1902/(ISSN)1943-3670 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/JPER.18-0680 ↗
- Languages:
- English
- ISSNs:
- 0022-3492
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5030.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12115.xml