Automatic EPAP intelligent volume‐assured pressure support is effective in patients with chronic respiratory failure: A randomized trial. Issue 12 (22nd April 2019)
- Record Type:
- Journal Article
- Title:
- Automatic EPAP intelligent volume‐assured pressure support is effective in patients with chronic respiratory failure: A randomized trial. Issue 12 (22nd April 2019)
- Main Title:
- Automatic EPAP intelligent volume‐assured pressure support is effective in patients with chronic respiratory failure: A randomized trial
- Authors:
- Orr, Jeremy E.
Coleman, John
Criner, Gerard J.
Sundar, Krishna M.
Tsai, Sheila C.
Benjafield, Adam V.
Crocker, Maureen E.
Willes, Leslee
Malhotra, Atul
Owens, Robert L.
Wolfe, Lisa F. - Abstract:
- ABSTRACT: Background and objective: Patients with chronic respiratory failure are increasingly managed with domiciliary non‐invasive ventilation (NIV). There may be limited ability to provide NIV titration for these complex patients, and ventilatory requirements and upper airway support needs may change over time. Therefore, an automatically adjusting expiratory positive airway pressure (AutoEPAP) algorithm may offer advantages over manually adjusted EPAP for treating these patients. This study compared 4% oxygen desaturation index (ODI4%) values during the use of an AutoEPAP algorithm versus manual EPAP titration with the intelligent volume‐assured pressure support (iVAPS) algorithm. Methods: This prospective, single‐blind, randomized, crossover study was conducted at six US sites. Patients with chronic respiratory failure (neuromuscular disease, chronic obstructive pulmonary disease, obesity hypoventilation and other aetiologies) and an apnoea–hypopnoea index of >5/h who were already established NIV users underwent a single night of NIV with the iVAPS manual EPAP and iVAPS AutoEPAP in the sleep laboratory in random order. Results: A total of 38 patients constituted the study population. Mean ODI4% was statistically non‐inferior with AutoEPAP versus manual EPAP ( P < 0.0001). There was no difference in the effect on ODI4% across respiratory failure subgroups. Ventilation parameters and gas exchange were similar with either NIV mode, indicating equally effective treatment ofABSTRACT: Background and objective: Patients with chronic respiratory failure are increasingly managed with domiciliary non‐invasive ventilation (NIV). There may be limited ability to provide NIV titration for these complex patients, and ventilatory requirements and upper airway support needs may change over time. Therefore, an automatically adjusting expiratory positive airway pressure (AutoEPAP) algorithm may offer advantages over manually adjusted EPAP for treating these patients. This study compared 4% oxygen desaturation index (ODI4%) values during the use of an AutoEPAP algorithm versus manual EPAP titration with the intelligent volume‐assured pressure support (iVAPS) algorithm. Methods: This prospective, single‐blind, randomized, crossover study was conducted at six US sites. Patients with chronic respiratory failure (neuromuscular disease, chronic obstructive pulmonary disease, obesity hypoventilation and other aetiologies) and an apnoea–hypopnoea index of >5/h who were already established NIV users underwent a single night of NIV with the iVAPS manual EPAP and iVAPS AutoEPAP in the sleep laboratory in random order. Results: A total of 38 patients constituted the study population. Mean ODI4% was statistically non‐inferior with AutoEPAP versus manual EPAP ( P < 0.0001). There was no difference in the effect on ODI4% across respiratory failure subgroups. Ventilation parameters and gas exchange were similar with either NIV mode, indicating equally effective treatment of respiratory failure. Sleep parameters were improved during AutoEPAP versus manual EPAP. Conclusion: A single night of NIV using the iVAPS with AutoEPAP algorithm was non‐inferior to a single night of iVAPS with manual EPAP titration in patients with respiratory failure.Clinical Trial Registration: NCT02683772 at clinicaltrials.gov Abstract : Automated expiratory positive airway pressure (EPAP) titration may be helpful in treating patients with respiratory failure and upper airway obstruction. This study demonstrates that, for a single night's titration, an automated EPAP algorithm is as effective as manually set EPAP for treating desaturation, without compromising ventilation and potentially improving sleep quality. See related Editorial … (more)
- Is Part Of:
- Respirology. Volume 24:Issue 12(2019)
- Journal:
- Respirology
- Issue:
- Volume 24:Issue 12(2019)
- Issue Display:
- Volume 24, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 24
- Issue:
- 12
- Issue Sort Value:
- 2019-0024-0012-0000
- Page Start:
- 1204
- Page End:
- 1211
- Publication Date:
- 2019-04-22
- Subjects:
- chronic obstructive pulmonary disease -- neuromuscular disease -- non‐invasive ventilation -- obesity hypoventilation syndrome -- respiratory failure
Respiratory organs -- Diseases -- Periodicals
Respiratory organs -- Periodicals
612.2 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=res ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/resp.13546 ↗
- Languages:
- English
- ISSNs:
- 1323-7799
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.666000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12123.xml