New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs. (23rd October 2019)
- Record Type:
- Journal Article
- Title:
- New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs. (23rd October 2019)
- Main Title:
- New Circumpapillary Retinal Nerve Fiber Layer Thickness and Bruch's Membrane Opening-Minimum Rim Width Assessment in Nonglaucomatous Eyes with Large Discs
- Authors:
- Bayraktar, Serife
Sultanova, Gulnar
Cebeci, Zafer
Altinkurt, Emre
Izgi, Belgin - Other Names:
- Thomas Biju B. Academic Editor.
- Abstract:
- Abstract : Purpose . To compare the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch's membrane opening (BMO), RNFLBMO1, with the conventional circumpapillary RNFL thickness measurement centered on the optic disc (RNFLDİ ), and assess the BMO-minimum rim width (BMO-MRW) in nonglaucomatous eyes with large discs. Methods . This prospective, cross-sectional, observational study included a total of 91 eyes of 91 patients having nonglaucomatous eyes with large discs (Group 1) and 50 eyes of 50 healthy subjects (Group 2). The optic nerve head (ONH) parameters obtained by confocal scanning laser ophthalmoscopy (CSLO), peripapillary RNFL thickness, BMO area, and BMO-MRW were imaged with SD-OCT. Results . The mean disc size was 3.06 ± 0.42 mm 2 (range, 2.61–4.68) in Group 1 and 1.95 ± 0.23 mm 2 (range, 1.6–2.43) in Group 2 (p = 0.0001 ). The mean BMO area was 2.9 ± 0.58 mm 2 (range, 1.26–4.62) in Group 1 and 2.05 ± 0.31 mm 2 (range, 1.51–2.82) in Group 2 (p = 0.0001 ). The difference between RNFLDİ and RNFLBMO1 measurements in Group 1 was stronger than in Group 2 because it was significant in all sectors in large discs. The mean global BMO-MRW thickness was significantly thinner in large discs; it was 252.95 ± 42.16 µ (range, 170–420) in Group 1 and 326.06 ± 73.39 µ (range, 210–440) in Group 2 (p = 0.0001 ). There was a positive correlation between BMO-MRW thicknessAbstract : Purpose . To compare the new spectral-domain optical coherence tomography (SD-OCT) algorithm for measuring circumpapillary retinal nerve fiber layer (RNFL) thickness centered on Bruch's membrane opening (BMO), RNFLBMO1, with the conventional circumpapillary RNFL thickness measurement centered on the optic disc (RNFLDİ ), and assess the BMO-minimum rim width (BMO-MRW) in nonglaucomatous eyes with large discs. Methods . This prospective, cross-sectional, observational study included a total of 91 eyes of 91 patients having nonglaucomatous eyes with large discs (Group 1) and 50 eyes of 50 healthy subjects (Group 2). The optic nerve head (ONH) parameters obtained by confocal scanning laser ophthalmoscopy (CSLO), peripapillary RNFL thickness, BMO area, and BMO-MRW were imaged with SD-OCT. Results . The mean disc size was 3.06 ± 0.42 mm 2 (range, 2.61–4.68) in Group 1 and 1.95 ± 0.23 mm 2 (range, 1.6–2.43) in Group 2 (p = 0.0001 ). The mean BMO area was 2.9 ± 0.58 mm 2 (range, 1.26–4.62) in Group 1 and 2.05 ± 0.31 mm 2 (range, 1.51–2.82) in Group 2 (p = 0.0001 ). The difference between RNFLDİ and RNFLBMO1 measurements in Group 1 was stronger than in Group 2 because it was significant in all sectors in large discs. The mean global BMO-MRW thickness was significantly thinner in large discs; it was 252.95 ± 42.16 µ (range, 170–420) in Group 1 and 326.06 ± 73.39 µ (range, 210–440) in Group 2 (p = 0.0001 ). There was a positive correlation between BMO-MRW thickness measurements and RNFL thickness parameters, both with RNFLDİ and RNFLBMO1, in global and all optic nerve sectors except temporal quadrants with r = 0.257–0.431 (p ≤ 0.001 – 0.01 ) in Group 1. But in control group, Group 2, there was a weak correlation or no correlation between BMO-MRW thickness measurements and RNFL thickness parameters with r = −0.256–0.328 (p = 0.797 – 0.02 ). Conclusion . The new circumpapillary RNFL scanning algorithm centered on BMO is better to assess the RNFL thickness and BMO-MRW in large discs for the early diagnosis of glaucoma. … (more)
- Is Part Of:
- Journal of ophthalmology. Volume 2019(2019)
- Journal:
- Journal of ophthalmology
- Issue:
- Volume 2019(2019)
- Issue Display:
- Volume 2019, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 2019
- Issue:
- 2019
- Issue Sort Value:
- 2019-2019-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10-23
- Subjects:
- Ophthalmology -- Periodicals
Eye Diseases
Ophthalmology
Ophthalmology
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
Periodicals
617.7 - Journal URLs:
- https://www.hindawi.com/journals/joph/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1195/ ↗
http://bibpurl.oclc.org/web/46495 ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%229038%22&scope=site ↗ - DOI:
- 10.1155/2019/3431217 ↗
- Languages:
- English
- ISSNs:
- 2090-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12104.xml