Quantitative PET/MR imaging of lung cancer in the presence of artifacts in the MR-based attenuation correction maps. (January 2020)
- Record Type:
- Journal Article
- Title:
- Quantitative PET/MR imaging of lung cancer in the presence of artifacts in the MR-based attenuation correction maps. (January 2020)
- Main Title:
- Quantitative PET/MR imaging of lung cancer in the presence of artifacts in the MR-based attenuation correction maps
- Authors:
- Kuttner, Samuel
Lassen, Martin Lyngby
Øen, Silje Kjærnes
Sundset, Rune
Beyer, Thomas
Eikenes, Live - Abstract:
- Background: Positron emission tomography (PET)/magnetic resonance (MR) imaging may become increasingly important for assessing tumor therapy response. A prerequisite for quantitative PET/MR imaging is reliable and repeatable MR-based attenuation correction (AC). Purpose: To investigate the frequency and test–retest reproducibility of artifacts in MR-AC maps in a lung cancer patient cohort and to study the impact of artifact corrections on PET-based tumor quantification. Material and Methods: Twenty-five lung cancer patients underwent single-day, test–retest, 18 F-fluorodeoxyglucose (FDG) PET/MR imaging. The acquired MR-AC maps were inspected for truncation, susceptibility, and tissue inversion artifacts. An anatomy-based bone template and a PET-based estimation of truncated arms were employed, while susceptibility artifacts were corrected manually. We report the frequencies of artifacts and the relative difference (RD) on standardized uptake value (SUV) based quantification in PET images reconstructed with the corrected AC maps. Results: Truncation artifacts were found in all 50 acquisitions (100%), while susceptibility and tissue inversion artifacts were observed in six (12%) and 26 (52%) of the scans, respectively. The RD in lung tumor SUV was < 5% from bone and truncation corrections, while up to 20% RD was introduced after susceptibility artifact correction, with large inconsistencies between test–retest scans. Conclusion: The absence of bone and truncation artifactsBackground: Positron emission tomography (PET)/magnetic resonance (MR) imaging may become increasingly important for assessing tumor therapy response. A prerequisite for quantitative PET/MR imaging is reliable and repeatable MR-based attenuation correction (AC). Purpose: To investigate the frequency and test–retest reproducibility of artifacts in MR-AC maps in a lung cancer patient cohort and to study the impact of artifact corrections on PET-based tumor quantification. Material and Methods: Twenty-five lung cancer patients underwent single-day, test–retest, 18 F-fluorodeoxyglucose (FDG) PET/MR imaging. The acquired MR-AC maps were inspected for truncation, susceptibility, and tissue inversion artifacts. An anatomy-based bone template and a PET-based estimation of truncated arms were employed, while susceptibility artifacts were corrected manually. We report the frequencies of artifacts and the relative difference (RD) on standardized uptake value (SUV) based quantification in PET images reconstructed with the corrected AC maps. Results: Truncation artifacts were found in all 50 acquisitions (100%), while susceptibility and tissue inversion artifacts were observed in six (12%) and 26 (52%) of the scans, respectively. The RD in lung tumor SUV was < 5% from bone and truncation corrections, while up to 20% RD was introduced after susceptibility artifact correction, with large inconsistencies between test–retest scans. Conclusion: The absence of bone and truncation artifacts have limited effect on the PET quantification of lung lesions. In contrast, susceptibility artifacts caused significant and inconsistent underestimations of the lung tumor SUVs, between test–retest scans. This may have clinical implications for patients undergoing serial imaging for tumor therapy response assessment. … (more)
- Is Part Of:
- Acta radiologica. Volume 61:Number 1(2020)
- Journal:
- Acta radiologica
- Issue:
- Volume 61:Number 1(2020)
- Issue Display:
- Volume 61, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 61
- Issue:
- 1
- Issue Sort Value:
- 2020-0061-0001-0000
- Page Start:
- 11
- Page End:
- 20
- Publication Date:
- 2020-01
- Subjects:
- PET/MR -- lung cancer -- attenuation correction -- artifacts
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185119848118 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12082.xml