Optimal tube voltage for abdominal enhanced CT in children: a self-controlled study. (January 2020)
- Record Type:
- Journal Article
- Title:
- Optimal tube voltage for abdominal enhanced CT in children: a self-controlled study. (January 2020)
- Main Title:
- Optimal tube voltage for abdominal enhanced CT in children: a self-controlled study
- Authors:
- Sun, Jihang
Zhang, Qifeng
Zhou, Zuofu
Jia, Chenguang
Yang, Wei
Li, Haoyan
Peng, Yun - Abstract:
- Background: The use of weight-adapted pediatric computed tomography (CT) tube voltage protocols has been suggested, but a consensus standard has not been established and clinical available studies are not sufficient. Purpose: To determine the best tube voltage for low dose abdominal CT imaging in children. Material and Methods: Eighty-seven cases who needed three CT exams in a 1–3-month interval between scans were enrolled (mean age = 4.69 ± 3.20 years). The three scans were performed with three different tube voltages at 80 kV, 100 kV, and 120 kV, keeping the same radiation dose and same contrast injection protocol. Patients were divided into five groups for analysis based on their body weight. The subjective image quality of the three exams were evaluated using a 4-point scale (4 being the best) for image noise and image quality. The objective evaluation in terms of CT values and standard deviation in aorta, liver, spleen, pancreas, and kidney were measured to calculate the degree of enhancement and contrast-to-noise ratio (CNR) of organs. One-way ANOVA was used to compare the subjective and objective image quality with respect to different tube voltages and different patient weights. Result: The 80-kV tube voltage provided the highest overall enhancement and CNR for the entire patient population and the best objective image quality for the 6.1–28.0 kg subgroup. Conclusion: Patient weight-dependent tube voltage selection maximizes image quality for abdominal enhanced CT inBackground: The use of weight-adapted pediatric computed tomography (CT) tube voltage protocols has been suggested, but a consensus standard has not been established and clinical available studies are not sufficient. Purpose: To determine the best tube voltage for low dose abdominal CT imaging in children. Material and Methods: Eighty-seven cases who needed three CT exams in a 1–3-month interval between scans were enrolled (mean age = 4.69 ± 3.20 years). The three scans were performed with three different tube voltages at 80 kV, 100 kV, and 120 kV, keeping the same radiation dose and same contrast injection protocol. Patients were divided into five groups for analysis based on their body weight. The subjective image quality of the three exams were evaluated using a 4-point scale (4 being the best) for image noise and image quality. The objective evaluation in terms of CT values and standard deviation in aorta, liver, spleen, pancreas, and kidney were measured to calculate the degree of enhancement and contrast-to-noise ratio (CNR) of organs. One-way ANOVA was used to compare the subjective and objective image quality with respect to different tube voltages and different patient weights. Result: The 80-kV tube voltage provided the highest overall enhancement and CNR for the entire patient population and the best objective image quality for the 6.1–28.0 kg subgroup. Conclusion: Patient weight-dependent tube voltage selection maximizes image quality for abdominal enhanced CT in children. The optimal tube voltage for children with weight <28 kg is 80 kV; higher voltages should be selected for children weighing 28.1–50.0 kg. … (more)
- Is Part Of:
- Acta radiologica. Volume 61:Number 1(2020)
- Journal:
- Acta radiologica
- Issue:
- Volume 61:Number 1(2020)
- Issue Display:
- Volume 61, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 61
- Issue:
- 1
- Issue Sort Value:
- 2020-0061-0001-0000
- Page Start:
- 101
- Page End:
- 109
- Publication Date:
- 2020-01
- Subjects:
- Computed tomography (CT) -- abdomen -- low tube voltage -- children -- radiation dose
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185119847683 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12082.xml