Ablation of typical atrial flutter guided by the paced PR interval on the surface electrocardiogram: a proof of concept study. Issue 11 (5th August 2019)
- Record Type:
- Journal Article
- Title:
- Ablation of typical atrial flutter guided by the paced PR interval on the surface electrocardiogram: a proof of concept study. Issue 11 (5th August 2019)
- Main Title:
- Ablation of typical atrial flutter guided by the paced PR interval on the surface electrocardiogram: a proof of concept study
- Authors:
- Madaffari, Antonio
Krisai, Philipp
Spies, Florian
Knecht, Sven
Schaer, Beat
Kojic, Dejan
Kühne, Michael
Sticherling, Christian
Osswald, Stefan - Abstract:
- Abstract: Aims: We aimed to assess the novel concept of using the paced PR interval (PRI) on the surface electrocardiogram (ECG) to prove trans-isthmus block after cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFl). Methods and results: Consecutive patients with AFl underwent linear radiofrequency ablation of the inferior CTI (6 o'clock). After AFl termination and/or presumed completion of the CTI line, CTI block was proven by atrial pacing by the ablation catheter medial (5 o'clock) and lateral to the line (7 and 9 o'clock). Corresponding PRIs were measured on the surface ECG. CTI block was assumed, if a sudden increase in the PRI was observed by moving the pacing site from 5 to 7 o'clock, and if the latter was longer than at 9 o'clock. Afterwards, bidirectional CTI block was confirmed by differential pacing. Thirty-one patients (mean age 67 ± 16 years, 81% male) underwent CTI ablation, and 18/31 (58%) were in AFl at the time of ablation (cycle length 249 ± 31 ms). Successful CTI block as defined by the PRI method was achieved in 31/31 (100%), and the mean PRIs during pacing at 5, 7, and 9 o'clock were 203 ± 56 ms, 329 ± 70 ms, and 296 ± 66 ms, respectively. Cavotricuspid isthmus block was confirmed in all patients (100%) by coronary sinus pacing with a reversal of the local activation sequence lateral to the isthmus line. Conclusion: The method of PRI analysis on the surface ECG to guide CTI ablation is easy to apply and highly accurate in confirming CTIAbstract: Aims: We aimed to assess the novel concept of using the paced PR interval (PRI) on the surface electrocardiogram (ECG) to prove trans-isthmus block after cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFl). Methods and results: Consecutive patients with AFl underwent linear radiofrequency ablation of the inferior CTI (6 o'clock). After AFl termination and/or presumed completion of the CTI line, CTI block was proven by atrial pacing by the ablation catheter medial (5 o'clock) and lateral to the line (7 and 9 o'clock). Corresponding PRIs were measured on the surface ECG. CTI block was assumed, if a sudden increase in the PRI was observed by moving the pacing site from 5 to 7 o'clock, and if the latter was longer than at 9 o'clock. Afterwards, bidirectional CTI block was confirmed by differential pacing. Thirty-one patients (mean age 67 ± 16 years, 81% male) underwent CTI ablation, and 18/31 (58%) were in AFl at the time of ablation (cycle length 249 ± 31 ms). Successful CTI block as defined by the PRI method was achieved in 31/31 (100%), and the mean PRIs during pacing at 5, 7, and 9 o'clock were 203 ± 56 ms, 329 ± 70 ms, and 296 ± 66 ms, respectively. Cavotricuspid isthmus block was confirmed in all patients (100%) by coronary sinus pacing with a reversal of the local activation sequence lateral to the isthmus line. Conclusion: The method of PRI analysis on the surface ECG to guide CTI ablation is easy to apply and highly accurate in confirming CTI block. This simple technique enables the novel concept of CTI ablation and proof of block with a single catheter. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 11(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 11(2019)
- Issue Display:
- Volume 21, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 11
- Issue Sort Value:
- 2019-0021-0011-0000
- Page Start:
- 1750
- Page End:
- 1754
- Publication Date:
- 2019-08-05
- Subjects:
- Atrial flutter -- Electrical mapping -- Radiofrequency catheter ablation -- Novel concept -- Cavotricuspid isthmus
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euz208 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: