Can we expect improvements in outcomes with centrifugal vs axial flow left ventricular assist devices in patients transitioned from extracorporeal life support?. Issue 11 (3rd September 2019)
- Record Type:
- Journal Article
- Title:
- Can we expect improvements in outcomes with centrifugal vs axial flow left ventricular assist devices in patients transitioned from extracorporeal life support?. Issue 11 (3rd September 2019)
- Main Title:
- Can we expect improvements in outcomes with centrifugal vs axial flow left ventricular assist devices in patients transitioned from extracorporeal life support?
- Authors:
- Urban, Marian
Siddique, Aleem
Moulton, Michael M.
Castleberry, Anthony W.
Merritt‐Genore, HelenMari
Ryan, Timothy
Lowes, Brian
Um, John Y. - Abstract:
- Abstract: Background: Several patient‐related characteristics have been associated with inferior outcomes following durable left ventricular assist device (LVAD) implantation in patients transitioned from venoarterial extracorporeal membrane oxygenation (VA ECMO). The impact of LVAD pump type used is less well‐known. Methods: We compared outcomes between patents who received axial and centrifugal flow LVADs following stabilization with VA ECMO. Results: From January 2011 to December 2018, we implanted 28 LVADs in patients transitioned from VA ECMO. This included 17 axial flow devices (HeartMate II LVAD, Abbott Laboratories, Chicago, IL) and 11 centrifugal flow pumps (eight HeartWare HVADs; Medtronic, Minneapolis, MN and three HeartMate 3 LVAS pumps; Abbott Laboratories, Chicago, IL). There was no difference in hospital mortality (23.5% vs 18.2%, P = .74) or 1‐year survival ( P = .31) between the devices. There were no differences in adverse event rates between the two pump types, apart from a higher rate of gastrointestinal bleeding in patients who received centrifugal flow pumps (1.44 events per 100 patient‐months vs 14.67 events per 100 patient‐months, P = .010). Preimplantation levels of alanine aminotransferase (hazard ratio [HR], 1.001; 95% confidence interval [CI], 1.000 to 1.002; P = .004) and elevated serum creatinine level (HR, 3.480; 95% CI, 1.121–10.807; P = .031) emerged as significant predictors of decreased 1‐year survival. Conclusions: PreimplantationAbstract: Background: Several patient‐related characteristics have been associated with inferior outcomes following durable left ventricular assist device (LVAD) implantation in patients transitioned from venoarterial extracorporeal membrane oxygenation (VA ECMO). The impact of LVAD pump type used is less well‐known. Methods: We compared outcomes between patents who received axial and centrifugal flow LVADs following stabilization with VA ECMO. Results: From January 2011 to December 2018, we implanted 28 LVADs in patients transitioned from VA ECMO. This included 17 axial flow devices (HeartMate II LVAD, Abbott Laboratories, Chicago, IL) and 11 centrifugal flow pumps (eight HeartWare HVADs; Medtronic, Minneapolis, MN and three HeartMate 3 LVAS pumps; Abbott Laboratories, Chicago, IL). There was no difference in hospital mortality (23.5% vs 18.2%, P = .74) or 1‐year survival ( P = .31) between the devices. There were no differences in adverse event rates between the two pump types, apart from a higher rate of gastrointestinal bleeding in patients who received centrifugal flow pumps (1.44 events per 100 patient‐months vs 14.67 events per 100 patient‐months, P = .010). Preimplantation levels of alanine aminotransferase (hazard ratio [HR], 1.001; 95% confidence interval [CI], 1.000 to 1.002; P = .004) and elevated serum creatinine level (HR, 3.480; 95% CI, 1.121–10.807; P = .031) emerged as significant predictors of decreased 1‐year survival. Conclusions: Preimplantation optimization of end‐organ function is the single most important determinant of successful post‐LVAD survival in patients transitioned from extracorporeal life support. There is no association of pump type with LVAD outcomes up to 1‐year post implantation. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 34:Issue 11(2019)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 34:Issue 11(2019)
- Issue Display:
- Volume 34, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2019-0034-0011-0000
- Page Start:
- 1228
- Page End:
- 1234
- Publication Date:
- 2019-09-03
- Subjects:
- clinical review -- left ventricular assist device -- mechanical circulatory support -- venoarterial extracorporeal membrane oxygenation
Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.14232 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12056.xml