Electro Fenton removal of clopyralid in soil washing effluents. (December 2019)
- Record Type:
- Journal Article
- Title:
- Electro Fenton removal of clopyralid in soil washing effluents. (December 2019)
- Main Title:
- Electro Fenton removal of clopyralid in soil washing effluents
- Authors:
- Carboneras Contreras, María Belén
Fourcade, Florence
Assadi, Aymen
Amrane, Abdeltif
Fernandez-Morales, Francisco Jesus - Abstract:
- Abstract: The removal of a commercial herbicide, based on clopyralid, by means of Electro-Fenton (EF) was studied using a soil washing effluent obtained using synthetic ground water as washing fluid. From the results, it was observed that the degradation and mineralization yields of clopyralid were high, even without the addition of supporting electrolyte. The groundwater could be then used as a sustainable supporting electrolyte. The influence of the minerals constituents, the current and the ferrous ions regeneration was evaluated. The highest hydrogen peroxide production was achieved working at 200 mA but regeneration of ferrous ions was not efficient at this current. Iodide ions were one of the main responsible in the EF efficiency decrease due to their reaction with the produced hydrogen peroxide. Electrochemical study proved that clopyralid was not electroactive and that its degradation was mainly due to radical oxidation. Long duration electrolysis carried out at 200 mA in groundwater provided an improvement of the solution biodegradability after 480 min that can be linked to a significant increase in the carboxylic acids production. These results support the feasibility of applying an EF process in order to carry out a subsequent biological mineralization. Highlights: Clopyralid removal by Electro-Fenton was studied. Groundwater was a supporting electrolyte presenting good results. KI contained in the groundwater negatively influenced the efficiency of the process.Abstract: The removal of a commercial herbicide, based on clopyralid, by means of Electro-Fenton (EF) was studied using a soil washing effluent obtained using synthetic ground water as washing fluid. From the results, it was observed that the degradation and mineralization yields of clopyralid were high, even without the addition of supporting electrolyte. The groundwater could be then used as a sustainable supporting electrolyte. The influence of the minerals constituents, the current and the ferrous ions regeneration was evaluated. The highest hydrogen peroxide production was achieved working at 200 mA but regeneration of ferrous ions was not efficient at this current. Iodide ions were one of the main responsible in the EF efficiency decrease due to their reaction with the produced hydrogen peroxide. Electrochemical study proved that clopyralid was not electroactive and that its degradation was mainly due to radical oxidation. Long duration electrolysis carried out at 200 mA in groundwater provided an improvement of the solution biodegradability after 480 min that can be linked to a significant increase in the carboxylic acids production. These results support the feasibility of applying an EF process in order to carry out a subsequent biological mineralization. Highlights: Clopyralid removal by Electro-Fenton was studied. Groundwater was a supporting electrolyte presenting good results. KI contained in the groundwater negatively influenced the efficiency of the process. High H2 O2 generation but low ferrous ion regeneration were achieved at 200 mA. Using Na2 SO4 as supporting electrolyte increased the clopyralid removal efficiency. … (more)
- Is Part Of:
- Chemosphere. Volume 237(2019)
- Journal:
- Chemosphere
- Issue:
- Volume 237(2019)
- Issue Display:
- Volume 237, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 237
- Issue:
- 2019
- Issue Sort Value:
- 2019-0237-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- Electro-Fenton -- Clopyralid -- Groundwater -- Soil washing effluent -- Biodegradability improvement
Pollution -- Periodicals
Pollution -- Physiological effect -- Periodicals
Environmental sciences -- Periodicals
Atmospheric chemistry -- Periodicals
551.511 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00456535/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.chemosphere.2019.124447 ↗
- Languages:
- English
- ISSNs:
- 0045-6535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.280000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12019.xml