Error detection using an electromagnetic tracking system in multi-catheter breast interstitial brachytherapy. (21st October 2019)
- Record Type:
- Journal Article
- Title:
- Error detection using an electromagnetic tracking system in multi-catheter breast interstitial brachytherapy. (21st October 2019)
- Main Title:
- Error detection using an electromagnetic tracking system in multi-catheter breast interstitial brachytherapy
- Authors:
- Masitho, Siti
Kallis, Karoline
Strnad, Vratislav
Fietkau, Rainer
Bert, Christoph - Abstract:
- Abstract: The hybrid treatment delivery system (HTDS) has been proposed as a possible option for a quality assurance in the multi-catheter interstitial brachytherapy for breast cancer patients. The system, which consists out of a prototype afterloader with an integrated electromagnetic tracking (EMT) sensor and an EMT system, allows the automatic measurement of implanted catheters. To test the feasibility of the system for error detection, possible treatment planning errors and treatment delivery errors were simulated. Planning errors such as an incorrect offset value, an incorrect indexer length, tip/connector end swaps, and partial swaps, and; treatment delivery errors such as catheter shifts and catheter connection swaps were manually simulated using phantoms. An in-house Matlab routine was used to assess geometrical deviations between the dwell positions defined based on CT and EMT measurement. Additionally, the influence of implant motion on the detection ability of the system was assessed. An algorithm for the detection and specification of errors based on the error simulation results was developed. At the University Hospital Erlangen, a patient study is ongoing, where errors in patient data were analyzed using the proposed algorithm. All simulated planning errors were detected. Catheter connection swaps can be detected 100% of the time. A shift detection rate of >97% was observed for shifts larger than 1.1 mm, both in the static and the motion measurements. CatheterAbstract: The hybrid treatment delivery system (HTDS) has been proposed as a possible option for a quality assurance in the multi-catheter interstitial brachytherapy for breast cancer patients. The system, which consists out of a prototype afterloader with an integrated electromagnetic tracking (EMT) sensor and an EMT system, allows the automatic measurement of implanted catheters. To test the feasibility of the system for error detection, possible treatment planning errors and treatment delivery errors were simulated. Planning errors such as an incorrect offset value, an incorrect indexer length, tip/connector end swaps, and partial swaps, and; treatment delivery errors such as catheter shifts and catheter connection swaps were manually simulated using phantoms. An in-house Matlab routine was used to assess geometrical deviations between the dwell positions defined based on CT and EMT measurement. Additionally, the influence of implant motion on the detection ability of the system was assessed. An algorithm for the detection and specification of errors based on the error simulation results was developed. At the University Hospital Erlangen, a patient study is ongoing, where errors in patient data were analyzed using the proposed algorithm. All simulated planning errors were detected. Catheter connection swaps can be detected 100% of the time. A shift detection rate of >97% was observed for shifts larger than 1.1 mm, both in the static and the motion measurements. Catheter reconstruction uncertainties and catheter shifts <2 mm were found to be the most common treatment planning and delivery errors in patient data. HTDS proved to be a reliable method for error detection. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 64:Number 20(2019:Oct.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 64:Number 20(2019:Oct.)
- Issue Display:
- Volume 64, Issue 20 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 20
- Issue Sort Value:
- 2019-0064-0020-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10-21
- Subjects:
- quality assurance -- interstitial brachytherapy -- electromagnetic tracking -- breast cancer
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ab4336 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12031.xml