Nakamura, Masato - Abstract:
- We evaluated intra- and interobserver variability of quantitative coronary angiography (QCA) due to cine frame selection for 9 coronary stenoses. The projection was selected in advance. Cine frames were selected by 2 blinded experts (blind frame QCA) followed by assignment by supervisor (pre-selected frame QCA). Each expert analyzed 18 frames twice with a 3-month interval. A total of 72 measurements by 2 experts were used for intra- and interobserver variability analysis in calibration factor (CF), minimal lumen diameter (MLD), percent diameter stenosis (%DS), interpolated reference diameter (Int R), and lesion length (LL). Accuracy, precision, and coefficient of variation (CV) were calculated based on 2 measurements. For interobserver variability, intraclass correlation coefficient (ICC) was evaluated. Regarding intraobserver variability, precision (CV) was 0.0026 (1.45), 0.220 (25.1), 0.282 (11.0), 7.626 (11.8), and 4.042 (28.7) for blind frame QCA and 0.0044 (2.46), 0.094 (11.2), 0.225 (8.6), 3.924 (5.9), and 1.941 (12.1) for pre-selected frame QCA and regarding interobserver variability, precision (CV) was 0.0037 (2.09), 0.271 (31.8), 0.307 (11.9), 10.10 (15.4), and 5.121 (39.5) for blind frame QCA and 0.0050 (2.82), 0.098 (11.4), 0.246 (9.5), 5.253 (8.0), and 2.857 (19.0) for pre-selected frame QCA in CF, MLD, Int R, %DS, and LL, respectively. Intraclass correlation coefficient of Int R was almost perfect in blind and pre-selected frame QCA. Intraclass correlationWe evaluated intra- and interobserver variability of quantitative coronary angiography (QCA) due to cine frame selection for 9 coronary stenoses. The projection was selected in advance. Cine frames were selected by 2 blinded experts (blind frame QCA) followed by assignment by supervisor (pre-selected frame QCA). Each expert analyzed 18 frames twice with a 3-month interval. A total of 72 measurements by 2 experts were used for intra- and interobserver variability analysis in calibration factor (CF), minimal lumen diameter (MLD), percent diameter stenosis (%DS), interpolated reference diameter (Int R), and lesion length (LL). Accuracy, precision, and coefficient of variation (CV) were calculated based on 2 measurements. For interobserver variability, intraclass correlation coefficient (ICC) was evaluated. Regarding intraobserver variability, precision (CV) was 0.0026 (1.45), 0.220 (25.1), 0.282 (11.0), 7.626 (11.8), and 4.042 (28.7) for blind frame QCA and 0.0044 (2.46), 0.094 (11.2), 0.225 (8.6), 3.924 (5.9), and 1.941 (12.1) for pre-selected frame QCA and regarding interobserver variability, precision (CV) was 0.0037 (2.09), 0.271 (31.8), 0.307 (11.9), 10.10 (15.4), and 5.121 (39.5) for blind frame QCA and 0.0050 (2.82), 0.098 (11.4), 0.246 (9.5), 5.253 (8.0), and 2.857 (19.0) for pre-selected frame QCA in CF, MLD, Int R, %DS, and LL, respectively. Intraclass correlation coefficient of Int R was almost perfect in blind and pre-selected frame QCA. Intraclass correlation coefficient of MLD, %DS, and LL were substantial/lower by blind frame QCA and improved to almost perfect by pre-selected frame QCA. Blind cine film selection might affect intra- and interobserver variability, especially in MLD and LL. In the multiple linear regression analysis, blind frame QCA was selected as an explanatory factor of QCA variability in MLD, %DS, and LL. The error range due to frame selection must be taken into consideration in clinical use. … (more)
- Is Part Of:
- Clinical Medicine Insights. Issue 13(2019)
- Journal:
- Clinical Medicine Insights
- Issue:
- Issue 13(2019)
- Issue Display:
- Volume 13, Issue 13 (2019)
- Year:
- 2019
- Volume:
- 13
- Issue:
- 13
- Issue Sort Value:
- 2019-0013-0013-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03
- Subjects:
- quantitative coronary angiography -- core laboratory -- frame selection -- cardiac cycle -- coronary intervention -- minimal lumen diameter -- coronary stenosis
Cardiovascular system -- Diseases -- Periodicals
Cardiology -- Periodicals
Cardiovascular Diseases
Cardiology
Cardiovascular system -- Diseases
Electronic journals
Periodicals
Fulltext
Internet Resources
Periodicals
Periodicals
616.12 - Journal URLs:
- http://bibpurl.oclc.org/web/46469 ↗
http://www.la-press.com/clinical-medicine-insights-cardiology-journal-j48 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1227/ ↗
http://journals.sagepub.com/home/cic ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1179546819838232 ↗
- Languages:
- English
- ISSNs:
- 1179-5468
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12018.xml