Resuscitative endovascular balloon occlusion of the aorta induced myocardial injury is mitigated by endovascular variable aortic control. Issue 3 (September 2019)
- Record Type:
- Journal Article
- Title:
- Resuscitative endovascular balloon occlusion of the aorta induced myocardial injury is mitigated by endovascular variable aortic control. Issue 3 (September 2019)
- Main Title:
- Resuscitative endovascular balloon occlusion of the aorta induced myocardial injury is mitigated by endovascular variable aortic control
- Authors:
- Beyer, Carl A.
Hoareau, Guillaume L.
Tibbits, Emily M.
Davidson, Anders J.
DeSoucy, Erik D.
Simon, Meryl A.
Grayson, John Kevin
Neff, Lucas P.
Williams, Timothy K.
Johnson, Michael Austin - Abstract:
- Abstract : BACKGROUND: The cardiac effects of resuscitative endovascular balloon occlusion of the aorta (REBOA) are largely unknown. We hypothesized that increased afterload from REBOA would lead to cardiac injury, and that partial flow using endovascular variable aortic control (EVAC) would mitigate this injury. METHODS: Eighteen anesthetized swine underwent controlled 25% blood volume hemorrhage. Animals were randomized to either Zone 1 REBOA, Zone 1 EVAC, or no intervention (control) for 45 minutes. Animals were then resuscitated with shed blood, observed during critical care, and euthanized after a 6-hour total experimental time. Left ventricular function was measured with a pressure-volume catheter, and blood samples were drawn at routine intervals. RESULTS: The average cardiac output during the intervention period was higher in the REBOA group (9.3 [8.6–15.4] L/min) compared with the EVAC group (7.2 [5.8–8.0] L/min, p = 0.01) and the control group (6.8 [5.8–7.7] L/min, p < 0.01). At the end of the intervention, the preload recruitable stroke work was significantly higher in both the REBOA and EVAC groups compared with the control group (111.2 [102.5–148.6] and 116.7 [116.6–141.4] vs. 67.1 [62.7–87.9], p = 0.02 and p < 0.01, respectively). The higher preload recruitable stroke work was maintained throughout the experiment in the EVAC group, but not in the REBOA group. Serum troponin concentrations after 6 hours were higher in the REBOA group compared with both the EVACAbstract : BACKGROUND: The cardiac effects of resuscitative endovascular balloon occlusion of the aorta (REBOA) are largely unknown. We hypothesized that increased afterload from REBOA would lead to cardiac injury, and that partial flow using endovascular variable aortic control (EVAC) would mitigate this injury. METHODS: Eighteen anesthetized swine underwent controlled 25% blood volume hemorrhage. Animals were randomized to either Zone 1 REBOA, Zone 1 EVAC, or no intervention (control) for 45 minutes. Animals were then resuscitated with shed blood, observed during critical care, and euthanized after a 6-hour total experimental time. Left ventricular function was measured with a pressure-volume catheter, and blood samples were drawn at routine intervals. RESULTS: The average cardiac output during the intervention period was higher in the REBOA group (9.3 [8.6–15.4] L/min) compared with the EVAC group (7.2 [5.8–8.0] L/min, p = 0.01) and the control group (6.8 [5.8–7.7] L/min, p < 0.01). At the end of the intervention, the preload recruitable stroke work was significantly higher in both the REBOA and EVAC groups compared with the control group (111.2 [102.5–148.6] and 116.7 [116.6–141.4] vs. 67.1 [62.7–87.9], p = 0.02 and p < 0.01, respectively). The higher preload recruitable stroke work was maintained throughout the experiment in the EVAC group, but not in the REBOA group. Serum troponin concentrations after 6 hours were higher in the REBOA group compared with both the EVAC and control groups (6.26 ± 5.35 ng/mL vs 0.92 ± 0.61 ng/mL and 0.65 ± 0.38 ng/mL, p = 0.05 and p = 0.03, respectively). Cardiac intramural hemorrhage was higher in the REBOA group compared with the control group (1.67 ± 0.46 vs. 0.17 ± 0.18, p = 0.03), but not between the EVAC and control groups. CONCLUSION: In a swine model of hemorrhagic shock, complete aortic occlusion resulted in cardiac injury, although there was no direct decrease in cardiac function. EVAC mitigated the cardiac injury and improved cardiac performance during resuscitation and critical care. … (more)
- Is Part Of:
- Journal of trauma and acute care surgery. Volume 87:Issue 3(2019)
- Journal:
- Journal of trauma and acute care surgery
- Issue:
- Volume 87:Issue 3(2019)
- Issue Display:
- Volume 87, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 87
- Issue:
- 3
- Issue Sort Value:
- 2019-0087-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09
- Subjects:
- Resuscitative endovascular balloon occlusion of the aorta -- endovascular variable aortic control -- myocardial injury -- partial aortic occlusion -- hemorrhage control
Surgical intensive care -- Periodicals
Surgical emergencies -- Periodicals
Wounds and injuries -- Surgery -- Periodicals
617.026 - Journal URLs:
- http://journals.lww.com/jtrauma/pages/default.aspx ↗
http://ovidsp.tx.ovid.com/sp-3.5.0b/ovidweb.cgi?&S=NEIKFPIGHGDDBOHLNCALMDIBGLDKAA00&Browse=Toc+Children%7cNO%7cS.sh.2697_1327404888_15.2697_1327404888_27.2697_1327404888_28%7c273%7c50 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/TA.0000000000002363 ↗
- Languages:
- English
- ISSNs:
- 2163-0755
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5070.510500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12032.xml