Novel fluorescent sensor using molecularly imprinted silica microsphere‐coated CdSe@CdS quantum dots and its application in the detection of 2, 4, 6‐trichlorophenol from environmental water samples. (12th June 2019)
- Record Type:
- Journal Article
- Title:
- Novel fluorescent sensor using molecularly imprinted silica microsphere‐coated CdSe@CdS quantum dots and its application in the detection of 2, 4, 6‐trichlorophenol from environmental water samples. (12th June 2019)
- Main Title:
- Novel fluorescent sensor using molecularly imprinted silica microsphere‐coated CdSe@CdS quantum dots and its application in the detection of 2, 4, 6‐trichlorophenol from environmental water samples
- Authors:
- Liu, Yang
Chen, Piaopiao
Zheng, Shan
Xing, Yichen
Huang, Chaobiao - Abstract:
- Abstract: In this study, a high fluorescence sensitivity and selectivity, molecularly imprinted nanofluorescent polymer sensor (MIP@SiO2 @QDs) was prepared using a reverse microemulsion method. 2, 4, 6‐Trichlorophenol (2, 4, 6‐TCP) was detected using fluorescence quenching. Tetraethyl orthosilicate (TEOS), quantum dots (QDs) and 3‐aminopropyltriethoxysilane (APTS) were used as cross‐linker, signal sources and functional monomer respectively. The sensor (MIP@SiO2 @QDs) and the non‐imprinted polymer sensor (NIP@SiO2 @QDs) were characterized using infra‐red (IR) analysis, X‐ray diffraction (XRD), transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The selectivity of MIP@SiO2 @QDs was examined by comparing 2, 4, 6‐TCP with other similar functional substances including 2, 4‐dichlorophenol (2, 4‐DCP), 2, 6‐dichlorophenol (2, 6‐DCP) and 4‐chlorophenol (4‐CP). Results showed that MIP@SiO2 @QDs had better selectivity for 2, 4, 6‐TCP than the other compounds. Fluorescence quenching efficiency displayed a good linear response at the 2, 4, 6‐TCP concentration range 5–1000 μmol/L. The limit of detection (LOD) was 0.9 μmol/L (3σ, n = 9). This method was equally applicable for testing actual samples with a recovery rate of 98.0–105.8%. The sensor had advantages of simple pretreatment, good sensitivity and selectivity, and wide linear range and could be applied for the rapid detection of 2, 4, 6‐TCP in actual samples.
- Is Part Of:
- Luminescence. Volume 34:Number 7(2019)
- Journal:
- Luminescence
- Issue:
- Volume 34:Number 7(2019)
- Issue Display:
- Volume 34, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 34
- Issue:
- 7
- Issue Sort Value:
- 2019-0034-0007-0000
- Page Start:
- 680
- Page End:
- 688
- Publication Date:
- 2019-06-12
- Subjects:
- 2, 4, 6‐trichlorophenol -- fluorescence -- molecularly imprinted polymers -- quantum dots
Luminescence -- Periodicals
Bioluminescence -- Periodicals
Chemiluminescence -- Periodicals
Luminescence -- Periodicals
535.35 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bio.3653 ↗
- Languages:
- English
- ISSNs:
- 1522-7235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5304.782850
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12004.xml