Clinical Image Coregistration Variability on a Dedicated Radiosurgery Unit. Issue 1 (19th July 2018)
- Record Type:
- Journal Article
- Title:
- Clinical Image Coregistration Variability on a Dedicated Radiosurgery Unit. Issue 1 (19th July 2018)
- Main Title:
- Clinical Image Coregistration Variability on a Dedicated Radiosurgery Unit
- Authors:
- Ruschin, Mark
Sahgal, Arjun
Soliman, Hany
Myrehaug, Sten
Tseng, Chia-Lin
Bola, Ruby
Yeboah, Collins
Sarfehnia, Arman
Chugh, Brige
Eriksson, Markus
Nordström, Håkan
Lee, Young - Abstract:
- Abstract: BACKGROUND: On a new dedicated radiosurgery unit enabling frameless treatments, a cone-beam computed tomography (CBCT) can be used for stereotactic definition. Since magnetic resonance imaging (MRI) is used to delineate target, reproducible MRI-to-CBCT coregistration is vital for accurate target localization. OBJECTIVE: To evaluate reproducibility of image coregistration in patient images. METHODS: Three types of coregistration (source-to-target) were analyzed: (1) MRI-to-CT; (2) MRI-to-CBCT; and (3) CT-to-CBCT. For each patient (n = 15), each coregistration type was independently performed 5 to 30 times (total: 465 coregistrations). Each coregistration yielded a transformation matrix, which was subsequently applied to transform every point in the source image to stereotactic coordinates. Two metrics were measured: (1) target registration error (TRE): mean distance between the registered position of each target point and the average registration position of that point; (2) compound registration error (CRE): mean spatial difference between stereotactic coordinates using (A) MRI-to-CT-to-CBCT and (B) MRI-to-CBCT. RESULTS: The median (range) of TRE was 0.11 mm (0.06-0.22 mm), 0.17 mm (0.10-0.36 mm), and 0.12 mm (0.08-0.21 mm) for MRI-to-CT, MRI-to-CBCT, and CT-to-CBCT, respectively. The TRE for MRI-to-CBCT was statistically higher than the other 2 methods ( P < .01). The median (range) of CRE was 0.44 mm (0.22-0.59 mm). The maximum point CRE between patients rangedAbstract: BACKGROUND: On a new dedicated radiosurgery unit enabling frameless treatments, a cone-beam computed tomography (CBCT) can be used for stereotactic definition. Since magnetic resonance imaging (MRI) is used to delineate target, reproducible MRI-to-CBCT coregistration is vital for accurate target localization. OBJECTIVE: To evaluate reproducibility of image coregistration in patient images. METHODS: Three types of coregistration (source-to-target) were analyzed: (1) MRI-to-CT; (2) MRI-to-CBCT; and (3) CT-to-CBCT. For each patient (n = 15), each coregistration type was independently performed 5 to 30 times (total: 465 coregistrations). Each coregistration yielded a transformation matrix, which was subsequently applied to transform every point in the source image to stereotactic coordinates. Two metrics were measured: (1) target registration error (TRE): mean distance between the registered position of each target point and the average registration position of that point; (2) compound registration error (CRE): mean spatial difference between stereotactic coordinates using (A) MRI-to-CT-to-CBCT and (B) MRI-to-CBCT. RESULTS: The median (range) of TRE was 0.11 mm (0.06-0.22 mm), 0.17 mm (0.10-0.36 mm), and 0.12 mm (0.08-0.21 mm) for MRI-to-CT, MRI-to-CBCT, and CT-to-CBCT, respectively. The TRE for MRI-to-CBCT was statistically higher than the other 2 methods ( P < .01). The median (range) of CRE was 0.44 mm (0.22-0.59 mm). The maximum point CRE between patients ranged from 0.37-1.15 mm when considering all MRI points, but reduced to 0.31-0.90 mm within the central 16 cm. The CRE varied across the image volume, and typically was minimized near the center. CONCLUSION: The variation in image coregistration is within 0.2 mm, indicating a high degree of reproducibility. The CRE varies throughout the head but is submillimeter in the central 16 cm region. … (more)
- Is Part Of:
- Neurosurgery. Volume 85:Issue 1(2019)
- Journal:
- Neurosurgery
- Issue:
- Volume 85:Issue 1(2019)
- Issue Display:
- Volume 85, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 85
- Issue:
- 1
- Issue Sort Value:
- 2019-0085-0001-0000
- Page Start:
- E101
- Page End:
- E108
- Publication Date:
- 2018-07-19
- Subjects:
- Brain -- Cone-beam CT -- Gamma knife -- Image coregistration -- MRI -- Radiosurgery -- Stereotactic
Nervous system -- Surgery -- Periodicals
617.48005 - Journal URLs:
- https://academic.oup.com/neurosurgery ↗
http://www.neurosurgery-online.com ↗
https://journals.lww.com/neurosurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1093/neuros/nyy334 ↗
- Languages:
- English
- ISSNs:
- 0148-396X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.582000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12005.xml