Accuracy and Safety of Lateral Vertebral Notch-Referred Technique Used in Subaxial Cervical Pedicle Screw Placement. Issue 1 (4th September 2018)
- Record Type:
- Journal Article
- Title:
- Accuracy and Safety of Lateral Vertebral Notch-Referred Technique Used in Subaxial Cervical Pedicle Screw Placement. Issue 1 (4th September 2018)
- Main Title:
- Accuracy and Safety of Lateral Vertebral Notch-Referred Technique Used in Subaxial Cervical Pedicle Screw Placement
- Authors:
- Pan, Zhimin
Zhong, Junlong
Xie, Shiming
Yu, Limin
Wu, Chunyang
Ha, Yoon
Kim, Keung Nyun
Zhang, Youshan
Cao, Kai - Abstract:
- Abstract: BACKGROUND: Biomechanical studies revealed that pedicle screw instrumentation has a superior stabilizing effect compared with other internal fixations in reconstructing the subaxial cervical spine. However, severe neurovascular risks preclude surgeons from routinely conducting pedicle screw manipulation in cervical spine. OBJECTIVE: To evaluate the accuracy and safety of the lateral vertebral notch (LVN)-referred technique used in subaxial cervical pedicle screw (CPS) placement. METHODS: One hundred thirty-five consecutive retrospective patients with cervical disorders underwent the LVN-referred technique for CPS placements in 3 spine centers. Postoperative pedicle perforations were confirmed by CT scans to assess the technical accuracy. Neurovascular complications derived from CPS misplacements were recorded to evaluate the technical safety. RESULTS: A total of 718 CPSs were inserted into subaxial cervical spine. Postoperative CT scans revealed that the accuracy of CPS placement was superior. Neither vertebral artery injury nor spinal cord injury occurred. One radiculopathy was from a unilateral C6 nerve root compression. A screw-related neurovascular injury rate of 0.7% occurred in this cohort. Additionally, there was no significant difference in the accuracy of CPS placement among 3 surgeons (H = 1.460, P = .482). The relative standard deviation values revealed that technical reproducibility was acceptable. Furthermore, there was no significant differenceAbstract: BACKGROUND: Biomechanical studies revealed that pedicle screw instrumentation has a superior stabilizing effect compared with other internal fixations in reconstructing the subaxial cervical spine. However, severe neurovascular risks preclude surgeons from routinely conducting pedicle screw manipulation in cervical spine. OBJECTIVE: To evaluate the accuracy and safety of the lateral vertebral notch (LVN)-referred technique used in subaxial cervical pedicle screw (CPS) placement. METHODS: One hundred thirty-five consecutive retrospective patients with cervical disorders underwent the LVN-referred technique for CPS placements in 3 spine centers. Postoperative pedicle perforations were confirmed by CT scans to assess the technical accuracy. Neurovascular complications derived from CPS misplacements were recorded to evaluate the technical safety. RESULTS: A total of 718 CPSs were inserted into subaxial cervical spine. Postoperative CT scans revealed that the accuracy of CPS placement was superior. Neither vertebral artery injury nor spinal cord injury occurred. One radiculopathy was from a unilateral C6 nerve root compression. A screw-related neurovascular injury rate of 0.7% occurred in this cohort. Additionally, there was no significant difference in the accuracy of CPS placement among 3 surgeons (H = 1.460, P = .482). The relative standard deviation values revealed that technical reproducibility was acceptable. Furthermore, there was no significant difference between the patients' pedicle transverse angles and inserted CPS transverse angles from C3 to C7 (all P > .05). CONCLUSION: The LVN is a reliable and consistent anatomic landmark for CPS placement. The accuracy and safety of subaxial CPS placement by using LVN-referred technique are highly acceptable, which may endow this technique to be practicably performed in selected patients. … (more)
- Is Part Of:
- Operative neurosurgery. Volume 17:Issue 1(2019)
- Journal:
- Operative neurosurgery
- Issue:
- Volume 17:Issue 1(2019)
- Issue Display:
- Volume 17, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2019-0017-0001-0000
- Page Start:
- 52
- Page End:
- 60
- Publication Date:
- 2018-09-04
- Subjects:
- Lateral vertebral notch -- Accuracy and safety -- Subaxial cervical spine -- Pedicle screw
Nervous system -- Surgery -- Periodicals
617.480590 - Journal URLs:
- https://academic.oup.com/ons/issue ↗
http://journals.lww.com/onsonline/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1093/ons/opy233 ↗
- Languages:
- English
- ISSNs:
- 2332-4252
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6269.380200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11990.xml