Comparison of the sustainability of mitral annular dynamics between two semi-rigid annuloplasty devices. (15th February 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of the sustainability of mitral annular dynamics between two semi-rigid annuloplasty devices. (15th February 2019)
- Main Title:
- Comparison of the sustainability of mitral annular dynamics between two semi-rigid annuloplasty devices
- Authors:
- Bouchez, Stefaan
Timmermans, Frank
Philipsen, Tine
François, Katrien
Bové, Thierry - Abstract:
- Abstract: OBJECTIVES: The choice of annuloplasty device is fundamental at the time of mitral valve repair, the goal being to optimally restore the physiological 3-dimensional (3D) structure and dynamics of the mitral annulus (MA). This study evaluated MA dynamics after annuloplasty with 2 different semi-rigid devices. METHODS: Thirty-three patients eligible for mitral valve repair were selected for annuloplasty with the Physio II ring (Edwards Lifesciences, Irving, CA, USA) ( n = 17) or the Memo 3D ring (LivaNova, Saluggia, Italy) ( n = 16). MA dynamics were assessed with transoesophageal 3D echocardiography intraoperatively and 1 year after repair. RESULTS: The postoperative changes in the anteroposterior diameter {3.7% [standard deviation (SD) 2.7] vs 1.9% [SD 1.3]; P = 0.013} and in the annular height [27.7% (SD 8.7) vs 18.0% (SD 13.9); P = 0.003] were significantly larger with the Memo 3D ring during the cardiac cycle. The restoration of the saddle shape at baseline was superior with the Physio II ring, defined by a larger systolic annular height-to-commissural width ratio [15.1% (SD 2.3) vs 7.1% (SD 2.4); P < 0.001]. These observations of MA dynamics were sustained after 1 year, shown by a greater anteroposterior extension [5.1% (SD 1.0) vs 1.7% (SD 1.6); P = 0.002] and change in annular height-to-commissural width ratio [15.7% (SD 12.7) vs 3.1% (SD 3.0); P = 0.020] for the Memo 3D ring. There were no significant differences in mitral valve function between the 2Abstract: OBJECTIVES: The choice of annuloplasty device is fundamental at the time of mitral valve repair, the goal being to optimally restore the physiological 3-dimensional (3D) structure and dynamics of the mitral annulus (MA). This study evaluated MA dynamics after annuloplasty with 2 different semi-rigid devices. METHODS: Thirty-three patients eligible for mitral valve repair were selected for annuloplasty with the Physio II ring (Edwards Lifesciences, Irving, CA, USA) ( n = 17) or the Memo 3D ring (LivaNova, Saluggia, Italy) ( n = 16). MA dynamics were assessed with transoesophageal 3D echocardiography intraoperatively and 1 year after repair. RESULTS: The postoperative changes in the anteroposterior diameter {3.7% [standard deviation (SD) 2.7] vs 1.9% [SD 1.3]; P = 0.013} and in the annular height [27.7% (SD 8.7) vs 18.0% (SD 13.9); P = 0.003] were significantly larger with the Memo 3D ring during the cardiac cycle. The restoration of the saddle shape at baseline was superior with the Physio II ring, defined by a larger systolic annular height-to-commissural width ratio [15.1% (SD 2.3) vs 7.1% (SD 2.4); P < 0.001]. These observations of MA dynamics were sustained after 1 year, shown by a greater anteroposterior extension [5.1% (SD 1.0) vs 1.7% (SD 1.6); P = 0.002] and change in annular height-to-commissural width ratio [15.7% (SD 12.7) vs 3.1% (SD 3.0); P = 0.020] for the Memo 3D ring. There were no significant differences in mitral valve function between the 2 devices. CONCLUSIONS: The MA dynamics after annuloplasty with the Physio II and Memo 3D rings demonstrated a better systolic 3D restoration of the saddle shape with the Physio II ring, whereas the saddle-shaped geometry improved significantly with the Memo 3D ring, as a dynamic phenomenon. The Memo 3D ring also showed increased anteroposterior annular mobility and folding dynamics throughout the cardiac cycle. Moreover, the observed differences in MA dynamics between both devices appeared to be sustainable 1 year after ring implantation. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 56:Number 2(2019)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 56:Number 2(2019)
- Issue Display:
- Volume 56, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 56
- Issue:
- 2
- Issue Sort Value:
- 2019-0056-0002-0000
- Page Start:
- 360
- Page End:
- 368
- Publication Date:
- 2019-02-15
- Subjects:
- Mitral valve repair -- Mitral annulus -- 3-Dimensional echocardiography
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezz035 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11990.xml