A Simple Method for Peak Alignment Using Relative Retention Time Related to an Inherent Peak in Liquid Chromatography-Mass Spectrometry-Based Metabolomics. (31st July 2018)
- Record Type:
- Journal Article
- Title:
- A Simple Method for Peak Alignment Using Relative Retention Time Related to an Inherent Peak in Liquid Chromatography-Mass Spectrometry-Based Metabolomics. (31st July 2018)
- Main Title:
- A Simple Method for Peak Alignment Using Relative Retention Time Related to an Inherent Peak in Liquid Chromatography-Mass Spectrometry-Based Metabolomics
- Authors:
- Wang, Yang
Ma, Li
Zhang, Mengliu
Chen, Meiwan
Li, Peng
He, Chengwei
Yan, Chunyan
Wan, Jian-Bo - Abstract:
- Abstract: Retention time (RT) shifts are inevitable in liquid chromatography-mass spectrometry (LC–MS)-based metabolomics studies. RT alignment, aligning peaks originating from the same feature to an identical RT, is a necessary step prior to multivariate data analysis. Many RT alignment software packages and various algorithms have been developed. In the present study, a simple method for peak alignment was proposed using relative RT related to an inherent peak in the chromatogram, and its performance on RT alignment in untargeted metabolomics was evaluated using an LC–MS dataset acquired from plasma samples from osteoporotic rats, and compared with the common MarkerLynx XS method using different RT window. RT alignment accuracy and relative standard deviation (RSD) value of the intensity of 79 selected ions in a chromatogram were employed to assess the alignment effectiveness of Method I (0.2 RT window), Method II (0.5 RT window) and Method III (relative RT). The overall RT alignment accuracy of these three methods was 67.7%, 77.2% and 90.9%, and 44.3%, 72.2% and 82.3% of the ions had intensity RSD values <30%, respectively. The results demonstrated that Method III using relative RT significantly reduced the influence caused by RT shifts in LC–MS-based metabolomics. Furthermore, Method I and Method III were applied to discover plasma biomarkers for osteoporosis in rats. Thirteen and nineteen ions were selected as potential biomarkers, respectively. Among them, only eightAbstract: Retention time (RT) shifts are inevitable in liquid chromatography-mass spectrometry (LC–MS)-based metabolomics studies. RT alignment, aligning peaks originating from the same feature to an identical RT, is a necessary step prior to multivariate data analysis. Many RT alignment software packages and various algorithms have been developed. In the present study, a simple method for peak alignment was proposed using relative RT related to an inherent peak in the chromatogram, and its performance on RT alignment in untargeted metabolomics was evaluated using an LC–MS dataset acquired from plasma samples from osteoporotic rats, and compared with the common MarkerLynx XS method using different RT window. RT alignment accuracy and relative standard deviation (RSD) value of the intensity of 79 selected ions in a chromatogram were employed to assess the alignment effectiveness of Method I (0.2 RT window), Method II (0.5 RT window) and Method III (relative RT). The overall RT alignment accuracy of these three methods was 67.7%, 77.2% and 90.9%, and 44.3%, 72.2% and 82.3% of the ions had intensity RSD values <30%, respectively. The results demonstrated that Method III using relative RT significantly reduced the influence caused by RT shifts in LC–MS-based metabolomics. Furthermore, Method I and Method III were applied to discover plasma biomarkers for osteoporosis in rats. Thirteen and nineteen ions were selected as potential biomarkers, respectively. Among them, only eight common ions were found, which demonstrated that different sets of biomarkers were obtained using those two RT alignment methods. The relative RT method exhibited fewer missing values, a lower RSD of peak intensity and better performance in pattern recognition, thereby showing the great potential in future metabolomics studies. … (more)
- Is Part Of:
- Journal of chromatographic science. Volume 57:Number 1(2019)
- Journal:
- Journal of chromatographic science
- Issue:
- Volume 57:Number 1(2019)
- Issue Display:
- Volume 57, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 57
- Issue:
- 1
- Issue Sort Value:
- 2019-0057-0001-0000
- Page Start:
- 9
- Page End:
- 16
- Publication Date:
- 2018-07-31
- Subjects:
- Chromatographic analysis -- Periodicals
543.8 - Journal URLs:
- http://chromsci.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/chromsci/bmy074 ↗
- Languages:
- English
- ISSNs:
- 0021-9665
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11986.xml