Randomized comparison between epidural waveform analysis through the needle versus the catheter for thoracic epidural blocks. Issue 8 (August 2019)
- Record Type:
- Journal Article
- Title:
- Randomized comparison between epidural waveform analysis through the needle versus the catheter for thoracic epidural blocks. Issue 8 (August 2019)
- Main Title:
- Randomized comparison between epidural waveform analysis through the needle versus the catheter for thoracic epidural blocks
- Authors:
- Tangjitbampenbun, Amornrat
Layera, Sebastián
Arnuntasupakul, Vanlapa
Apinyachon, Worapot
Venegas, Karen
Godoy, Jaime
Aliste, Julián
Bravo, Daniela
Blanch, Alonso
Webar, Javier
Saadawi, Mohammed
Owen, Andrew
Finlayson, Roderick J
Tran, De Q - Abstract:
- Abstract : Background: Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss of resistance (LOR): when the needle/catheter tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. Epidural waveform analysis can be carried out through the tip of the needle (EWA-N) or the catheter (EWA-C). In this randomized trial, we compared the two methods. We hypothesized that, compared with EWA-C, EWA-N would result in a shorter performance time. Methods: One hundred and twenty patients undergoing thoracic epidural blocks for thoracic or abdominal surgery were randomized to EWA-N or EWA-C. In the EWA-N group, LOR was confirmed by connecting the epidural needle to a pressure transducer. After obtaining a satisfactory waveform, the epidural catheter was advanced 5 cm beyond the needle tip. In the EWA-C group, the epidural catheter was first advanced 5 cm beyond the needle tip after the occurrence of LOR. Subsequently, the catheter was connected to the pressure transducer to detect the presence of waveforms. In both study groups, the block procedure was repeated at different intervertebral levels until positive waveforms could be obtained (through the needle or catheter as per the allocation) or until a predefined maximum of three intervertebral levels had been reached. Subsequently, the operator administered a 4 mL test dose of lidocaine 2% with epinephrine 5 µg/mL through the catheter. An investigator presentAbstract : Background: Epidural waveform analysis (EWA) provides a simple confirmatory adjunct for loss of resistance (LOR): when the needle/catheter tip is correctly positioned inside the epidural space, pressure measurement results in a pulsatile waveform. Epidural waveform analysis can be carried out through the tip of the needle (EWA-N) or the catheter (EWA-C). In this randomized trial, we compared the two methods. We hypothesized that, compared with EWA-C, EWA-N would result in a shorter performance time. Methods: One hundred and twenty patients undergoing thoracic epidural blocks for thoracic or abdominal surgery were randomized to EWA-N or EWA-C. In the EWA-N group, LOR was confirmed by connecting the epidural needle to a pressure transducer. After obtaining a satisfactory waveform, the epidural catheter was advanced 5 cm beyond the needle tip. In the EWA-C group, the epidural catheter was first advanced 5 cm beyond the needle tip after the occurrence of LOR. Subsequently, the catheter was connected to the pressure transducer to detect the presence of waveforms. In both study groups, the block procedure was repeated at different intervertebral levels until positive waveforms could be obtained (through the needle or catheter as per the allocation) or until a predefined maximum of three intervertebral levels had been reached. Subsequently, the operator administered a 4 mL test dose of lidocaine 2% with epinephrine 5 µg/mL through the catheter. An investigator present during the performance of the block recorded the performance time (defined as the temporal interval between skin infiltration and local anesthetic administration through the epidural catheter). Fifteen minutes after the test dose, a blinded investigator assessed the patient for sensory block to ice. Success was defined as a bilateral block in at least two dermatomes. Furthermore, postoperative pain scores, local anesthetic consumption, and breakthrough analgesic consumption were recorded. Results: No intergroup differences were found in terms of performance time, success rate, postoperative pain, local anesthetic requirement, and breakthrough analgesic consumption. Conclusion: EWA can be carried out through the needle or through the catheter with similar efficiency (performance time) and efficacy (success rate, postoperative analgesia). Trial registration number: NCT03603574. … (more)
- Is Part Of:
- Regional anesthesia and pain medicine. Volume 44:Issue 8(2019)
- Journal:
- Regional anesthesia and pain medicine
- Issue:
- Volume 44:Issue 8(2019)
- Issue Display:
- Volume 44, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 44
- Issue:
- 8
- Issue Sort Value:
- 2019-0044-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- neuraxial blocks: epidural -- postoperative pain -- spinal/epidural injection
Conduction anesthesia -- Periodicals
Pain medicine -- Periodicals
617.964 - Journal URLs:
- http://www.rapm.org/ ↗
https://journals.lww.com/rapm/pages/default.aspx ↗
http://www.sciencedirect.com/science/journal/10987339 ↗
https://rapm.bmj.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1136/rapm-2019-100478 ↗
- Languages:
- English
- ISSNs:
- 1098-7339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7336.572210
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11968.xml