Correlation Between the Immediate Remnant Stump Length and Vein Diameter After Cyanoacrylate Closure Using the VenaSeal System During Treatment of an Incompetent Great Saphenous Vein. (January 2020)
- Record Type:
- Journal Article
- Title:
- Correlation Between the Immediate Remnant Stump Length and Vein Diameter After Cyanoacrylate Closure Using the VenaSeal System During Treatment of an Incompetent Great Saphenous Vein. (January 2020)
- Main Title:
- Correlation Between the Immediate Remnant Stump Length and Vein Diameter After Cyanoacrylate Closure Using the VenaSeal System During Treatment of an Incompetent Great Saphenous Vein
- Authors:
- Park, Insoo
Kim, Daehwan - Abstract:
- Objectives: Cyanoacrylate glue is injected for incompetent great saphenous vein (GSV) treatment 5 cm distal to the saphenofemoral junction (SFJ). Although a few reports have investigated the postprocedural remnant stump length, none have focused on the factors affecting glue extension length and the consequent remnant stump length. Methods: Seventy-nine patients undergoing cyanoacrylate closure using the VenaSeal system at our clinic between August 2018 and November 2018 were investigated. The GSV diameter was measured just before treatment in the supine position 3 cm distal to the SFJ. Cyanoacrylate glue was injected 5 cm distal to the SFJ. Results: The mean glue extension length was 1.13 ± 1.12 cm. The GSV diameter and glue extension length exhibited a significant inversely proportional relationship ( P < .001). More specifically, patients with a GSV diameter ≥0.7 cm had a longer remnant stump length than those with a smaller GSV diameter ( P < .001). Conclusions: An increased GSV diameter is likely associated with a decreased glue extension length and, consequently, a longer remnant stump.
- Is Part Of:
- Vascular & endovascular surgery. Volume 54:Number 1(2020)
- Journal:
- Vascular & endovascular surgery
- Issue:
- Volume 54:Number 1(2020)
- Issue Display:
- Volume 54, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 54
- Issue:
- 1
- Issue Sort Value:
- 2020-0054-0001-0000
- Page Start:
- 47
- Page End:
- 50
- Publication Date:
- 2020-01
- Subjects:
- cyanoacrylate closure -- VenaSeal -- varicose veins -- stump length -- great saphenous vein -- GSV
Blood-vessels -- Surgery -- Periodicals
Blood-vessels -- Endoscopic surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioplasty -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Vascular Diseases -- surgery -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
617.41 - Journal URLs:
- http://galenet.galegroup.com/servlet/HWRC?locIC=lcml_main ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00134449-000000000-00000 ↗
http://journals.sagepub.com/home/ves ↗
http://ves.sagepub.com ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1538574419879563 ↗
- Languages:
- English
- ISSNs:
- 1538-5744
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11966.xml