Value of ultrasound for access guidance and detection of subclinical vascular complications in the setting of atrial fibrillation cryoballoon ablation. Issue 3 (11th July 2018)
- Record Type:
- Journal Article
- Title:
- Value of ultrasound for access guidance and detection of subclinical vascular complications in the setting of atrial fibrillation cryoballoon ablation. Issue 3 (11th July 2018)
- Main Title:
- Value of ultrasound for access guidance and detection of subclinical vascular complications in the setting of atrial fibrillation cryoballoon ablation
- Authors:
- Ströker, Erwin
de Asmundis, Carlo
Kupics, Kaspars
Takarada, Ken
Mugnai, Giacomo
De Cocker, Jeroen
Stockman, Dirk
Sieira, Juan
Schwagten, Bruno
Brugada, Pedro
De Greef, Yves
Chierchia, Gian Battista - Abstract:
- Abstract: Aims: Vascular complications are the most common complications of atrial fibrillation (AF) ablation. Cryoballoon (CB) ablation for AF needs the insertion of a large 15 Fr sheath in the femoral vein. Our aim was to investigate the impact of vascular ultrasound (US) in guiding access and evaluating post-procedural subclinical complications in a large, multi-centre patient cohort that underwent CB ablation. Methods and results: A total cohort of 1435 consecutive patients were subdivided in 870 US −/−, 265 US −/+, and 300 US +/+ patients depending on US performance for: venipuncture guidance/post-procedural evaluation. Major clinical complications (requiring intervention and/or prolonged stay) were assessed. Irrespective of the clinical status, major US events were systematically determined in the subgroups with US evaluation 1 day post-procedure, if evidence of inadvertent artery puncture/cannulation (communication between artery and collection or artery-vein, regardless of the thrombosis state). Major clinical events were encountered in 1.7% (15/870), 1.1% (3/265), and 0% of patients in US −/−, US −/+, and US +/+ group, respectively ( P = 0.02 between US −/− and US +/+ group). In the US −/− group, 5/10 (50%) of pseudo-aneurysms were diagnosed during readmission after a mean of 24 ± 11 days post-procedure. No delayed presentation was seen in the US −/+ group. Major US events during the US protocol post-procedure were seen in 3.8% (10/265) vs. 0.3% (1/300) ofAbstract: Aims: Vascular complications are the most common complications of atrial fibrillation (AF) ablation. Cryoballoon (CB) ablation for AF needs the insertion of a large 15 Fr sheath in the femoral vein. Our aim was to investigate the impact of vascular ultrasound (US) in guiding access and evaluating post-procedural subclinical complications in a large, multi-centre patient cohort that underwent CB ablation. Methods and results: A total cohort of 1435 consecutive patients were subdivided in 870 US −/−, 265 US −/+, and 300 US +/+ patients depending on US performance for: venipuncture guidance/post-procedural evaluation. Major clinical complications (requiring intervention and/or prolonged stay) were assessed. Irrespective of the clinical status, major US events were systematically determined in the subgroups with US evaluation 1 day post-procedure, if evidence of inadvertent artery puncture/cannulation (communication between artery and collection or artery-vein, regardless of the thrombosis state). Major clinical events were encountered in 1.7% (15/870), 1.1% (3/265), and 0% of patients in US −/−, US −/+, and US +/+ group, respectively ( P = 0.02 between US −/− and US +/+ group). In the US −/− group, 5/10 (50%) of pseudo-aneurysms were diagnosed during readmission after a mean of 24 ± 11 days post-procedure. No delayed presentation was seen in the US −/+ group. Major US events during the US protocol post-procedure were seen in 3.8% (10/265) vs. 0.3% (1/300) of patients in US −/+ vs. US +/+ group, respectively, P = 0.004. Conclusion: US-guided venipuncture was associated with a near-to-zero risk of vascular complications in our patients undergoing CB ablation. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 3(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 3(2019)
- Issue Display:
- Volume 21, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 3
- Issue Sort Value:
- 2019-0021-0003-0000
- Page Start:
- 434
- Page End:
- 439
- Publication Date:
- 2018-07-11
- Subjects:
- Atrial fibrillation ablation -- Second-generation cryoballoon -- Ultrasound-guided vascular access -- Vascular access complications
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euy154 ↗
- Languages: