A simple and reliable ultra-high performance liquid chromatography coupled with tandem mass spectrometry method for simultaneous quantification of tyrosine and its metabolites in human urine. Issue 17 (8th November 2018)
- Record Type:
- Journal Article
- Title:
- A simple and reliable ultra-high performance liquid chromatography coupled with tandem mass spectrometry method for simultaneous quantification of tyrosine and its metabolites in human urine. Issue 17 (8th November 2018)
- Main Title:
- A simple and reliable ultra-high performance liquid chromatography coupled with tandem mass spectrometry method for simultaneous quantification of tyrosine and its metabolites in human urine
- Authors:
- Liu, Fan
Li, Bin
Yang, Yongli
Wan, Yiqun - Abstract:
- Abstract: In this paper, a fast and reliable method was developed for simultaneous quantification of tyrosine, 4-hydroxyphenyl acetic acid, 4-hydroxyphenyl lactic acid, 3-4-hydroxyphenyl propionic acid, 4-hydroxyphenethyl amine and 3-4-hydroxyphenyl alanine in human urine by ultra-high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UHPLC-Q-TOF-MS). The sample preparation procedure was simplified to obtain a fast analysis in terms of diluting the urine with ultrapure water and centrifuging pre-analysis. After estimating the matrix effect, matrix-matched calibration curves were used to equalize the matrix effect, and both chromatographic and MS conditions were optimized. To verify the reliability of this method, the performances of this method were validated carefully in terms of accuracy, precision, linearity, sensitivity, stability and carryover effect. The validation results showed that, the calibration cures were linear (correlation coefficients above 0.999), and the limits of detection and limits of quantification for the analytes were in the range of 0.003–0.081 mg/L and 0.010–0.270 mg/L, respectively. The recoveries were in the range of 85.5–110.0%, with RSDs of 0.8–4.2%. This method was further applied to human urine samples from normal people and cancer patients. All the results showed that this study might be helpful for development of noninvasive methods for cancer biomarkers discovering. Graphical Abstract:
- Is Part Of:
- Journal of liquid chromatography & related technologies. Volume 41:Issue 17/18(2018)
- Journal:
- Journal of liquid chromatography & related technologies
- Issue:
- Volume 41:Issue 17/18(2018)
- Issue Display:
- Volume 41, Issue 17/18 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 17/18
- Issue Sort Value:
- 2018-0041-NaN-0000
- Page Start:
- 1013
- Page End:
- 1019
- Publication Date:
- 2018-11-08
- Subjects:
- Urine -- Tyr and its metabolites -- ultra-high performance liquid chromatography- tandem quadrupole time-of-flight mass spectrometry -- biomarker
Liquid chromatography -- Periodicals
Chromatographic analysis -- Periodicals
Separation (Technology) -- Periodicals
Biotechnology -- Periodicals
Chromatography, Liquid -- Periodicals
543.8405 - Journal URLs:
- http://www.tandfonline.com/toc/ljlc20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10826076.2018.1556163 ↗
- Languages:
- English
- ISSNs:
- 1082-6076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.510500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11960.xml