The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children. Issue 4 (April 2019)
- Record Type:
- Journal Article
- Title:
- The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children. Issue 4 (April 2019)
- Main Title:
- The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children
- Authors:
- Lin, Sophia D.
Kahne, Kimberly R.
El Sherif, Amira
Mennitt, Kevin
Kessler, David
Ward, Mary J.
Platt, Shari L. - Abstract:
- Abstract : Objective: The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure. Methods: We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure. Results: We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively. Conclusions: Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shuntAbstract : Objective: The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure. Methods: We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure. Results: We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively. Conclusions: Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results. … (more)
- Is Part Of:
- Pediatric emergency care. Volume 35:Issue 4(2019)
- Journal:
- Pediatric emergency care
- Issue:
- Volume 35:Issue 4(2019)
- Issue Display:
- Volume 35, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 35
- Issue:
- 4
- Issue Sort Value:
- 2019-0035-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-04
- Subjects:
- bedside ultrasound -- pediatric shunt failure -- optic nerve sheath diameter
Pediatric emergencies -- Periodicals
618.92002505 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00006565-000000000-00000 ↗
http://www.pec-online.com ↗
http://journals.lww.com/pec-online/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PEC.0000000000001034 ↗
- Languages:
- English
- ISSNs:
- 0749-5161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11949.xml