Diagnostic Accuracy in Fit-for-Purpose PD-L1 Testing. Issue 4 (April 2019)
- Record Type:
- Journal Article
- Title:
- Diagnostic Accuracy in Fit-for-Purpose PD-L1 Testing. Issue 4 (April 2019)
- Main Title:
- Diagnostic Accuracy in Fit-for-Purpose PD-L1 Testing
- Authors:
- Cheung, Carol C.
Lim, Hyun J.
Garratt, John
Won, Jennifer
Gilks, C. Blake
Torlakovic, Emina E. - Abstract:
- Abstract : PD-L1 testing by immunohistochemistry (IHC) has presented significant challenges not only for clinical laboratories, but also for external quality assurance (EQA) entities that provide proficiency testing (PT) for clinical laboratories. Canadian Immunohistochemistry Quality Control (CIQC) has used educational runs to explore approaches to sample design and analysis of results that would enhance patient safety. As PT for predictive biomarkers requires modeling at every level (design of the run, assessment of the run, and reporting of "pass" or "fail") based on "fit-for-purpose" principles, CIQC has applied those principles to PD-L1 PT runs. Each laboratory received unstained slides with TMA tissue cores from 104 randomly selected primary NSCLC and tonsil tissues to test with their current PD-L1 assay. Diagnostic sensitivity and specificity were calculated against designated gold standards based on the "3D" approach (drug-disease-diagnostic assay). Depending on the selection of fit-for-purpose gold standards and also on the selection of what was considered fit-for-purpose cut-off points, great variation in the performance (accuracy) of both companion/complementary diagnostic assays and laboratory developed tests was seen. "Fit-for-purpose" in PT for PD-L1 testing entails that the purpose(s) of each PT run is declared a priori, that the PT program has selected/designated purpose-specific gold standard results for the PT challenge, and that the PT materials for the PTAbstract : PD-L1 testing by immunohistochemistry (IHC) has presented significant challenges not only for clinical laboratories, but also for external quality assurance (EQA) entities that provide proficiency testing (PT) for clinical laboratories. Canadian Immunohistochemistry Quality Control (CIQC) has used educational runs to explore approaches to sample design and analysis of results that would enhance patient safety. As PT for predictive biomarkers requires modeling at every level (design of the run, assessment of the run, and reporting of "pass" or "fail") based on "fit-for-purpose" principles, CIQC has applied those principles to PD-L1 PT runs. Each laboratory received unstained slides with TMA tissue cores from 104 randomly selected primary NSCLC and tonsil tissues to test with their current PD-L1 assay. Diagnostic sensitivity and specificity were calculated against designated gold standards based on the "3D" approach (drug-disease-diagnostic assay). Depending on the selection of fit-for-purpose gold standards and also on the selection of what was considered fit-for-purpose cut-off points, great variation in the performance (accuracy) of both companion/complementary diagnostic assays and laboratory developed tests was seen. "Fit-for-purpose" in PT for PD-L1 testing entails that the purpose(s) of each PT run is declared a priori, that the PT program has selected/designated purpose-specific gold standard results for the PT challenge, and that the PT materials for the PT run are designed and constructed to enable calculations of diagnostic accuracy. … (more)
- Is Part Of:
- Applied immunohistochemistry & molecular morphology. Volume 27:Issue 4(2019)
- Journal:
- Applied immunohistochemistry & molecular morphology
- Issue:
- Volume 27:Issue 4(2019)
- Issue Display:
- Volume 27, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2019-0027-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-04
- Subjects:
- PD-L1 -- quality assurance -- proficiency testing -- biomarker -- immunohistochemistry
Diagnostic immunohistochemistry -- Periodicals
Immunohistochemistry -- Periodicals
Cells -- Morphology -- Periodicals
Molecular diagnosis -- Periodicals
616.079 - Journal URLs:
- http://journals.lww.com/appliedimmunohist/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PAI.0000000000000734 ↗
- Languages:
- English
- ISSNs:
- 1541-2016
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1573.140000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11954.xml