Efficacy of robust optimization plan with partial‐arc VMAT for photon volumetric‐modulated arc therapy: A phantom study. (10th July 2017)
- Record Type:
- Journal Article
- Title:
- Efficacy of robust optimization plan with partial‐arc VMAT for photon volumetric‐modulated arc therapy: A phantom study. (10th July 2017)
- Main Title:
- Efficacy of robust optimization plan with partial‐arc VMAT for photon volumetric‐modulated arc therapy: A phantom study
- Authors:
- Miura, Hideharu
Ozawa, Shuichi
Nagata, Yasushi - Abstract:
- Abstract: This study investigated position dependence in planning target volume (PTV)‐based and robust optimization plans using full‐arc and partial‐arc volumetric modulated arc therapy (VMAT). The gantry angles at the periphery, intermediate, and center CTV positions were 181°–180° (full‐arc VMAT) and 181°–360° (partial‐arc VMAT). A PTV‐based optimization plan was defined by 5 mm margin expansion of the CTV to a PTV volume, on which the dose constraints were applied. The robust optimization plan consisted of a directly optimized dose to the CTV under a maximum‐uncertainties setup of 5 mm. The prescription dose was normalized to the CTV D99% (the minimum relative dose that covers 99% of the volume of the CTV) as an original plan. The isocenter was rigidly shifted at 1 mm intervals in the anterior‐posterior (A‐P), superior‐inferior (S‐I), and right‐left (R‐L) directions from the original position to the maximum‐uncertainties setup of 5 mm in the original plan, yielding recalculated dose distributions. It was found that for the intermediate and center positions, the uncertainties in the D99% doses to the CTV for all directions did not significantly differ when comparing the PTV‐based and robust optimization plans ( P > 0.05). For the periphery position, uncertainties in the D99% doses to the CTV in the R‐L direction for the robust optimization plan were found to be lower than those in the PTV‐based optimization plan ( P < 0.05). Our study demonstrated that a robustAbstract: This study investigated position dependence in planning target volume (PTV)‐based and robust optimization plans using full‐arc and partial‐arc volumetric modulated arc therapy (VMAT). The gantry angles at the periphery, intermediate, and center CTV positions were 181°–180° (full‐arc VMAT) and 181°–360° (partial‐arc VMAT). A PTV‐based optimization plan was defined by 5 mm margin expansion of the CTV to a PTV volume, on which the dose constraints were applied. The robust optimization plan consisted of a directly optimized dose to the CTV under a maximum‐uncertainties setup of 5 mm. The prescription dose was normalized to the CTV D99% (the minimum relative dose that covers 99% of the volume of the CTV) as an original plan. The isocenter was rigidly shifted at 1 mm intervals in the anterior‐posterior (A‐P), superior‐inferior (S‐I), and right‐left (R‐L) directions from the original position to the maximum‐uncertainties setup of 5 mm in the original plan, yielding recalculated dose distributions. It was found that for the intermediate and center positions, the uncertainties in the D99% doses to the CTV for all directions did not significantly differ when comparing the PTV‐based and robust optimization plans ( P > 0.05). For the periphery position, uncertainties in the D99% doses to the CTV in the R‐L direction for the robust optimization plan were found to be lower than those in the PTV‐based optimization plan ( P < 0.05). Our study demonstrated that a robust optimization plan's efficacy using partial‐arc VMAT depends on the periphery CTV position. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 5(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 5(2017)
- Issue Display:
- Volume 18, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 5
- Issue Sort Value:
- 2017-0018-0005-0000
- Page Start:
- 97
- Page End:
- 103
- Publication Date:
- 2017-07-10
- Subjects:
- arc angle -- robust treatment planning -- target position -- volumetric modulated arc therapy -- worst‐case scenario
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12131 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11951.xml