Implementation of absolute quantification in small‐animal SPECT imaging: Phantom and animal studies. (16th May 2017)
- Record Type:
- Journal Article
- Title:
- Implementation of absolute quantification in small‐animal SPECT imaging: Phantom and animal studies. (16th May 2017)
- Main Title:
- Implementation of absolute quantification in small‐animal SPECT imaging: Phantom and animal studies
- Authors:
- Gerdekoohi, Shabnam Khorasani
Vosoughi, Naser
Tanha, Kaveh
Assadi, Majid
Ghafarian, Pardis
Rahmim, Arman
Ay, Mohammad Reza - Abstract:
- Abstract: Purpose: Presence of photon attenuation severely challenges quantitative accuracy in single‐photon emission computed tomography (SPECT) imaging. Subsequently, various attenuation correction methods have been developed to compensate for this degradation. The present study aims to implement an attenuation correction method and then to evaluate quantification accuracy of attenuation correction in small‐animal SPECT imaging. Methods: Images were reconstructed using an iterative reconstruction method based on the maximum‐likelihood expectation maximization (MLEM) algorithm including resolution recovery. This was implemented in our designed dedicated small‐animal SPECT (HiReSPECT) system. For accurate quantification, the voxel values were converted to activity concentration via a calculated calibration factor. An attenuation correction algorithm was developed based on the first‐order Chang's method. Both phantom study and experimental measurements with four rats were used in order to validate the proposed method. Results: The phantom experiments showed that the error of −15.5% in the estimation of activity concentration in a uniform region was reduced to +5.1% when attenuation correction was applied. For in vivo studies, the average quantitative error of −22.8 ± 6.3% (ranging from −31.2% to −14.8%) in the uncorrected images was reduced to +3.5 ± 6.7% (ranging from −6.7 to +9.8%) after applying attenuation correction. Conclusion: The results indicate that the proposedAbstract: Purpose: Presence of photon attenuation severely challenges quantitative accuracy in single‐photon emission computed tomography (SPECT) imaging. Subsequently, various attenuation correction methods have been developed to compensate for this degradation. The present study aims to implement an attenuation correction method and then to evaluate quantification accuracy of attenuation correction in small‐animal SPECT imaging. Methods: Images were reconstructed using an iterative reconstruction method based on the maximum‐likelihood expectation maximization (MLEM) algorithm including resolution recovery. This was implemented in our designed dedicated small‐animal SPECT (HiReSPECT) system. For accurate quantification, the voxel values were converted to activity concentration via a calculated calibration factor. An attenuation correction algorithm was developed based on the first‐order Chang's method. Both phantom study and experimental measurements with four rats were used in order to validate the proposed method. Results: The phantom experiments showed that the error of −15.5% in the estimation of activity concentration in a uniform region was reduced to +5.1% when attenuation correction was applied. For in vivo studies, the average quantitative error of −22.8 ± 6.3% (ranging from −31.2% to −14.8%) in the uncorrected images was reduced to +3.5 ± 6.7% (ranging from −6.7 to +9.8%) after applying attenuation correction. Conclusion: The results indicate that the proposed attenuation correction algorithm based on the first‐order Chang's method, as implemented in our dedicated small‐animal SPECT system, significantly improves accuracy of the quantitative analysis as well as the absolute quantification. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 4(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 4(2017)
- Issue Display:
- Volume 18, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 4
- Issue Sort Value:
- 2017-0018-0004-0000
- Page Start:
- 215
- Page End:
- 223
- Publication Date:
- 2017-05-16
- Subjects:
- attenuation correction -- quantification -- small‐animal imaging -- SPECT imaging
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12094 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11949.xml