Comparison of three commercially available placental growth factor‐based tests in women with suspected preterm pre‐eclampsia: the COMPARE study. (5th December 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of three commercially available placental growth factor‐based tests in women with suspected preterm pre‐eclampsia: the COMPARE study. (5th December 2018)
- Main Title:
- Comparison of three commercially available placental growth factor‐based tests in women with suspected preterm pre‐eclampsia: the COMPARE study
- Authors:
- McCarthy, F. P.
Gill, C.
Seed, P. T.
Bramham, K.
Chappell, L. C.
Shennan, A. H. - Abstract:
- ABSTRACT: Objective: To compare the performance of three placental growth factor (PlGF)‐based tests in predicting delivery within 14 days from testing in women with suspected preterm pre‐eclampsia before 35 weeks' gestation. Methods: This was a retrospective analysis of samples collected from three prospective pregnancy cohort studies. Participants were pregnant women with suspected preterm pre‐eclampsia recruited in tertiary maternity units in the UK and Ireland. Samples were analyzed simultaneously according to the manufacturers' directions. The tests compared were the DELFIA Xpress PlGF 1‐2‐3 test, the Triage PlGF test and the Elecsys immunoassay soluble fms‐like tyrosine kinase‐1 (sFlt‐1)/PlGF ratio. Areas under receiver–operating characteristics curves (AUCs) were compared. The main outcome measure was detection of a difference of 0.05 in AUC between tests for delivery within 14 days of testing. Results: Plasma samples from 396 women and serum samples from 244 women were assayed. In predicting delivery within 14 days secondary to suspected pre‐eclampsia prior to 35 weeks' gestation, no significant differences were observed in AUCs ( P = 0.795), sensitivities ( P = 0.249), positive predictive values ( P = 0.765) or negative predictive values ( P = 0.920) between the three tests. The specificity of the Elecsys sFlt‐1/PlGF ratio test was higher than that of the other two tests ( P < 0.001). Conclusions: The tests perform similarly in their prediction of need forABSTRACT: Objective: To compare the performance of three placental growth factor (PlGF)‐based tests in predicting delivery within 14 days from testing in women with suspected preterm pre‐eclampsia before 35 weeks' gestation. Methods: This was a retrospective analysis of samples collected from three prospective pregnancy cohort studies. Participants were pregnant women with suspected preterm pre‐eclampsia recruited in tertiary maternity units in the UK and Ireland. Samples were analyzed simultaneously according to the manufacturers' directions. The tests compared were the DELFIA Xpress PlGF 1‐2‐3 test, the Triage PlGF test and the Elecsys immunoassay soluble fms‐like tyrosine kinase‐1 (sFlt‐1)/PlGF ratio. Areas under receiver–operating characteristics curves (AUCs) were compared. The main outcome measure was detection of a difference of 0.05 in AUC between tests for delivery within 14 days of testing. Results: Plasma samples from 396 women and serum samples from 244 women were assayed. In predicting delivery within 14 days secondary to suspected pre‐eclampsia prior to 35 weeks' gestation, no significant differences were observed in AUCs ( P = 0.795), sensitivities ( P = 0.249), positive predictive values ( P = 0.765) or negative predictive values ( P = 0.920) between the three tests. The specificity of the Elecsys sFlt‐1/PlGF ratio test was higher than that of the other two tests ( P < 0.001). Conclusions: The tests perform similarly in their prediction of need for delivery within 14 days in women with suspected pre‐eclampsia. The high negative predictive values support the role of PlGF‐based tests as 'rule‐out' tests for pre‐eclampsia. © 2018 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology. … (more)
- Is Part Of:
- Ultrasound in obstetrics & gynecology. Volume 53:Number 1(2019)
- Journal:
- Ultrasound in obstetrics & gynecology
- Issue:
- Volume 53:Number 1(2019)
- Issue Display:
- Volume 53, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 53
- Issue:
- 1
- Issue Sort Value:
- 2019-0053-0001-0000
- Page Start:
- 62
- Page End:
- 67
- Publication Date:
- 2018-12-05
- Subjects:
- DELFIA Xpress PlGF 1‐2‐3 test (Perkin Elmer) -- Elecsys immunoassay sFlt‐1/PlGF ratio (Roche) -- placental growth factor -- pre‐eclampsia -- soluble Flt‐1 -- Triage PlGF (Alere)
Ultrasonics in obstetrics -- Periodicals
Generative organs, Female -- Diseases -- Diagnosis -- Periodicals
Diagnosis, Ultrasonic -- Periodicals
Genital Diseases, Female -- ultrasonography -- Periodicals
Ultrasonography, Prenatal -- Periodicals
618.047543 - Journal URLs:
- http://obgyn.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1469-0705/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/uog.19051 ↗
- Languages:
- English
- ISSNs:
- 0960-7692
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11945.xml