Monitoring of tidal ventilation by electrical impedance tomography in anaesthetised horses. (18th August 2018)
- Record Type:
- Journal Article
- Title:
- Monitoring of tidal ventilation by electrical impedance tomography in anaesthetised horses. (18th August 2018)
- Main Title:
- Monitoring of tidal ventilation by electrical impedance tomography in anaesthetised horses
- Authors:
- Mosing, M.
Waldmann, A. D.
Raisis, A.
Böhm, S. H.
Drynan, E.
Wilson, K. - Abstract:
- Summary: Background: Electrical impedance tomography (EIT) is a method to measure regional impedance changes within the thorax. The total tidal impedance variation has been used to measure changes in tidal volumes in pigs, dogs and men. Objectives: To assess the ability of EIT to quantify changes in tidal volume in anaesthetised mechanically ventilated horses. Study design: In vivo experimental study. Methods: Six horses (mean ± s.d.: age 11.5 ± 7.5 years and body weight 491 ± 40 kg) were anaesthetised using isoflurane in oxygen. The lungs were mechanically ventilated using a volume‐controlled mode. With an end‐tidal carbon dioxide tension in the physiological range, and a set tidal volume (VTvent ) of 11–16 mL/kg (baseline volume), EIT data and VT measured by conventional spirometry were collected over 1 min. Thereafter, VTvent was changed in 1 L steps until reaching 10 L. After, VTvent was reduced to 1 L below the baseline volume and then further reduced in 1 L steps until 4 L. On each VT step data were recorded for 1 min after allowing 1 min of stabilisation. Impedance changes within the predefined two lung regions of interest (EITROI ) and the whole image (EITthorax ) were calculated. Linear regression analysis was used to assess the relationship between spirometry data and EITROI and EITthorax for individual horses and pooled data. Results: Both EITROI and EITthorax significantly predicted spirometry data for individual horses with R 2 ranging from 0.937 to 0.999 andSummary: Background: Electrical impedance tomography (EIT) is a method to measure regional impedance changes within the thorax. The total tidal impedance variation has been used to measure changes in tidal volumes in pigs, dogs and men. Objectives: To assess the ability of EIT to quantify changes in tidal volume in anaesthetised mechanically ventilated horses. Study design: In vivo experimental study. Methods: Six horses (mean ± s.d.: age 11.5 ± 7.5 years and body weight 491 ± 40 kg) were anaesthetised using isoflurane in oxygen. The lungs were mechanically ventilated using a volume‐controlled mode. With an end‐tidal carbon dioxide tension in the physiological range, and a set tidal volume (VTvent ) of 11–16 mL/kg (baseline volume), EIT data and VT measured by conventional spirometry were collected over 1 min. Thereafter, VTvent was changed in 1 L steps until reaching 10 L. After, VTvent was reduced to 1 L below the baseline volume and then further reduced in 1 L steps until 4 L. On each VT step data were recorded for 1 min after allowing 1 min of stabilisation. Impedance changes within the predefined two lung regions of interest (EITROI ) and the whole image (EITthorax ) were calculated. Linear regression analysis was used to assess the relationship between spirometry data and EITROI and EITthorax for individual horses and pooled data. Results: Both EITROI and EITthorax significantly predicted spirometry data for individual horses with R 2 ranging from 0.937 to 0.999 and from 0.954 to 0.997 respectively. This was similar for pooled data from all six horses with EITROI (R 2 = 0.799; P<0.001) and EITthorax (R 2 = 0.841; P<0.001). Main limitations: The method was only tested in healthy mechanically ventilated horses. Conclusions: The EIT can be used to quantify changes in tidal volume. … (more)
- Is Part Of:
- Equine veterinary journal. Volume 51:Number 2(2019)
- Journal:
- Equine veterinary journal
- Issue:
- Volume 51:Number 2(2019)
- Issue Display:
- Volume 51, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 51
- Issue:
- 2
- Issue Sort Value:
- 2019-0051-0002-0000
- Page Start:
- 222
- Page End:
- 226
- Publication Date:
- 2018-08-18
- Subjects:
- horse -- mechanical ventilation -- spirometry -- tidal impedance variation -- tidal volume
Horses -- Diseases -- Periodicals
636.108905 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1001/(ISSN)2042-3306 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.ingentaconnect.com/content/evj/evj ↗ - DOI:
- 10.1111/evj.12998 ↗
- Languages:
- English
- ISSNs:
- 0425-1644
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3794.520000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11933.xml