Accuracy and repeatability of a semi-quantitative barefoot pressure measurement method for clinical use: The Derks Calculation Method. (June 2019)
- Record Type:
- Journal Article
- Title:
- Accuracy and repeatability of a semi-quantitative barefoot pressure measurement method for clinical use: The Derks Calculation Method. (June 2019)
- Main Title:
- Accuracy and repeatability of a semi-quantitative barefoot pressure measurement method for clinical use: The Derks Calculation Method
- Authors:
- Maetzler, M.
Bochdansky, T.
Abboud, R.J. - Abstract:
- Highlights: The Derks Calculation Method is repeatable if the values for heel varus/valgus are excluded. The Derks Calculation Method was found to be accurate if the values for heel varus/valgus are excluded. The Derks Calculation Method is a viable tool when sophisticated computerised systems are not available. Abstract: Background: This study was designed to assess the accuracy and repeatability of the Derks Calculation Method in the normal foot during walking. Methods: Measurements were taken from 25 healthy subjects (age 32.0 ± 12.4), 23 females and 2 males, on five separate occasions at seven days, three weeks, three months, and nine months apart by means of a mid-gait method. Values were calculated for internal rotation (IR) and external rotation of the heel (ER), heel valgus/varus (HV), heel length (HL), heel width (HW), width of the midfoot (WM) and the forefoot (WF), and the length of the foot (LF). Results: For all five separate occasions and in 87.5% of the parameters investigated, the coefficient of repeatability (CR, expressed as a percentage of the mean) was less than 5%. One parameter showed a high CR - heel valgus/varus (HV) was extremely high (>800%). The maximum 95% Confidence Interval (CI) for the five different occasions was no higher than 0.2 cm for IR, ER and HV with a standard error (SE) of 0.01 and >0.01 respectively. The maximum 95% CI for WF was 0.4 cm (SE 0.1), and for HW, WM and LF the maximum 95% CI was 0.7 cm (SE 0.1 or 0.2). HL showed theHighlights: The Derks Calculation Method is repeatable if the values for heel varus/valgus are excluded. The Derks Calculation Method was found to be accurate if the values for heel varus/valgus are excluded. The Derks Calculation Method is a viable tool when sophisticated computerised systems are not available. Abstract: Background: This study was designed to assess the accuracy and repeatability of the Derks Calculation Method in the normal foot during walking. Methods: Measurements were taken from 25 healthy subjects (age 32.0 ± 12.4), 23 females and 2 males, on five separate occasions at seven days, three weeks, three months, and nine months apart by means of a mid-gait method. Values were calculated for internal rotation (IR) and external rotation of the heel (ER), heel valgus/varus (HV), heel length (HL), heel width (HW), width of the midfoot (WM) and the forefoot (WF), and the length of the foot (LF). Results: For all five separate occasions and in 87.5% of the parameters investigated, the coefficient of repeatability (CR, expressed as a percentage of the mean) was less than 5%. One parameter showed a high CR - heel valgus/varus (HV) was extremely high (>800%). The maximum 95% Confidence Interval (CI) for the five different occasions was no higher than 0.2 cm for IR, ER and HV with a standard error (SE) of 0.01 and >0.01 respectively. The maximum 95% CI for WF was 0.4 cm (SE 0.1), and for HW, WM and LF the maximum 95% CI was 0.7 cm (SE 0.1 or 0.2). HL showed the highest 95% CI (0.9 cm) with an SE of 0.2. Conclusion: The Derks Calculation Method was found to be accurate and repeatable if HV was excluded, which renders this method a viable clinical tool in settings where sophisticated computerised systems are still unavailable. … (more)
- Is Part Of:
- Foot. Volume 39(2019)
- Journal:
- Foot
- Issue:
- Volume 39(2019)
- Issue Display:
- Volume 39, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 2019
- Issue Sort Value:
- 2019-0039-2019-0000
- Page Start:
- 136
- Page End:
- 139
- Publication Date:
- 2019-06
- Subjects:
- Barefoot -- Pressure -- Derks -- Calculation Method -- Repeatability -- Accuracy
Foot -- Diseases -- Periodicals
Foot -- Surgery -- Periodicals
Foot Diseases -- Periodicals
Foot -- surgery -- Periodicals
Pied -- Maladies -- Périodiques
Pied -- Chirurgie -- Périodiques
Pied -- Lésions et blessures -- Périodiques
Foot -- Diseases
Foot -- Surgery
Periodicals
Electronic journals
Electronic journals
617.585005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09582592 ↗
http://www.harcourt-international.com/journals ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0958-2592;screen=info;ECOIP ↗
http://www.idealibrary.com/links/toc/foot/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09582592 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09582592 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.foot.2019.03.001 ↗
- Languages:
- English
- ISSNs:
- 0958-2592
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3984.840000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11909.xml