Pressure loss and performance assessment of horizontal spiral coil inserted pipes during forced convective evaporation of R-600a. (November 2019)
- Record Type:
- Journal Article
- Title:
- Pressure loss and performance assessment of horizontal spiral coil inserted pipes during forced convective evaporation of R-600a. (November 2019)
- Main Title:
- Pressure loss and performance assessment of horizontal spiral coil inserted pipes during forced convective evaporation of R-600a
- Authors:
- Alimardani, Farzam
Moghaddam, Hadi Ahmadi
Sarmadian, Alireza
Shafaee, Maziar - Abstract:
- Highlights: Spiral coils usage resulted in the pressure loss increase. Using inserts is beneficial at higher mass fluxes. The maximum performance factor of 1.4 was obtained by using inserts. A correlation for evaporative pressure drop of R-600a in rough pipes was developed. Abstract: The impacts of spiral coil inserts on the pressure loss of environment-friendly refrigerant R-600a are experimentally evaluated during forced convective evaporation within horizontal copper pipes. Then, by considering the current pressure drop and previous heat transfer results and calculating the performance factor, the overall effectiveness of the inserts is determined. Experiments are carried out for smooth and rough tubes. Five spiral coils with various coil pitches and wire diameters are utilized. Also, vapor qualities between 0.08 and 0.7 and mass fluxes between 109.2 and 505 kg m −2 s −1 are considered for tests. Generally, it is observed that inserts augment the pressure loss in the range of 90–958% over the smooth pipe. However, as the wire diameter decreases and the coil pitch increases, less pressure losses are imposed to the system. Depending on the operational conditions and inserts type, the performance factor was obtained between 0.13 and 1.40. The coiled wire "CW5" with the wire diameter of 1 mm and coil pitch of 30 mm performed superior compared to the other inserts by maximum performance factor of 1.4. Finally, by using the current data a new correlation is proposed in orderHighlights: Spiral coils usage resulted in the pressure loss increase. Using inserts is beneficial at higher mass fluxes. The maximum performance factor of 1.4 was obtained by using inserts. A correlation for evaporative pressure drop of R-600a in rough pipes was developed. Abstract: The impacts of spiral coil inserts on the pressure loss of environment-friendly refrigerant R-600a are experimentally evaluated during forced convective evaporation within horizontal copper pipes. Then, by considering the current pressure drop and previous heat transfer results and calculating the performance factor, the overall effectiveness of the inserts is determined. Experiments are carried out for smooth and rough tubes. Five spiral coils with various coil pitches and wire diameters are utilized. Also, vapor qualities between 0.08 and 0.7 and mass fluxes between 109.2 and 505 kg m −2 s −1 are considered for tests. Generally, it is observed that inserts augment the pressure loss in the range of 90–958% over the smooth pipe. However, as the wire diameter decreases and the coil pitch increases, less pressure losses are imposed to the system. Depending on the operational conditions and inserts type, the performance factor was obtained between 0.13 and 1.40. The coiled wire "CW5" with the wire diameter of 1 mm and coil pitch of 30 mm performed superior compared to the other inserts by maximum performance factor of 1.4. Finally, by using the current data a new correlation is proposed in order to predict the evaporative pressure loss of R-600a within spiral coil inserted pipes. … (more)
- Is Part Of:
- International journal of refrigeration. Volume 107(2019)
- Journal:
- International journal of refrigeration
- Issue:
- Volume 107(2019)
- Issue Display:
- Volume 107, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 107
- Issue:
- 2019
- Issue Sort Value:
- 2019-0107-2019-0000
- Page Start:
- 20
- Page End:
- 30
- Publication Date:
- 2019-11
- Subjects:
- Correlation -- Evaporation -- Pressure loss -- R-600a -- Spiral coil
Corrélation -- Évaporation -- Perte de pression -- R-600a -- Serpentin en spirale
Refrigeration and refrigerating machinery -- Periodicals
621.56 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/aip/01407007 ↗ - DOI:
- 10.1016/j.ijrefrig.2019.08.016 ↗
- Languages:
- English
- ISSNs:
- 0140-7007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.525500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11910.xml