Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications. (December 2019)
- Record Type:
- Journal Article
- Title:
- Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications. (December 2019)
- Main Title:
- Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications
- Authors:
- Ghosh, Subir
Abanteriba, Sylvester
Wong, Sherman
Houshyar, Shadi - Abstract:
- Abstract: The incidence of total hip arthroplasty (THA) has been evidently growing over the last few decades. Surface modification, such as polymer grafting onto implant surfaces using poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC), has been gaining attention due to its excellent biocompatibility and high lubricity behaviour resulting in reducing surgical recurrence number and increasing implant lifetime. Investigating thermal stability and mechanical properties of the grafted polymer is, therefore, extremely important as these properties define the failure mechanism of implants. This study focuses on optimising monomer concentration to achieve the best physical, thermal and mechanical properties of the grafted additively manufactured titanium (Ti6Al4V) implants. Three different concentration of monomers, 0.4 M, 0.6 M and 0.8 M, were investigated, and grafted implants were characterised. The results from thermal analysis confirmed that the PMPC polymer is thermally stable for implant applications regardless of the monomer concentrations. A significant reduction in Young's modulus of polymer grafted samples (33.2–42.9%), in comparison with untreated Ti6Al4V samples and consequent improvement of wear resistance and elasticity behaviour, proved the potentiality of polymer films for implant applications. In summary, polymer grafted implant prepared with 0.6 M monomer concentration showed the optimal thermal, physical and wear resistance properties. Highlights: PolyAbstract: The incidence of total hip arthroplasty (THA) has been evidently growing over the last few decades. Surface modification, such as polymer grafting onto implant surfaces using poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC), has been gaining attention due to its excellent biocompatibility and high lubricity behaviour resulting in reducing surgical recurrence number and increasing implant lifetime. Investigating thermal stability and mechanical properties of the grafted polymer is, therefore, extremely important as these properties define the failure mechanism of implants. This study focuses on optimising monomer concentration to achieve the best physical, thermal and mechanical properties of the grafted additively manufactured titanium (Ti6Al4V) implants. Three different concentration of monomers, 0.4 M, 0.6 M and 0.8 M, were investigated, and grafted implants were characterised. The results from thermal analysis confirmed that the PMPC polymer is thermally stable for implant applications regardless of the monomer concentrations. A significant reduction in Young's modulus of polymer grafted samples (33.2–42.9%), in comparison with untreated Ti6Al4V samples and consequent improvement of wear resistance and elasticity behaviour, proved the potentiality of polymer films for implant applications. In summary, polymer grafted implant prepared with 0.6 M monomer concentration showed the optimal thermal, physical and wear resistance properties. Highlights: Poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC) is thermally stable for physiological condition of hip joints. Optimal monomer concentration improved surface properties of PMPC grafted 3D implant. PMPC grafted implant reduced Young's modulus of the implant surface, which is closer to property of human bone.. Ti6Al4V exhibited the enhanced elasticity behavior after polymer grafting. PMPC grafting address the main issue in hip implant by improving wear resistance led in longer lifetime of the implant. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 100(2019)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 100(2019)
- Issue Display:
- Volume 100, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 100
- Issue:
- 2019
- Issue Sort Value:
- 2019-0100-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- Polymer grafting -- Selective laser melting (SLM) -- Implant -- Nanoindentation -- Total hip arthroplasty (THA) -- Poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC)
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2019.103412 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11906.xml