Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing. (December 2019)
- Record Type:
- Journal Article
- Title:
- Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing. (December 2019)
- Main Title:
- Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing
- Authors:
- Li, Richard L.
Russ, Jonathan
Paschalides, Costas
Ferrari, Giovanni
Waisman, Haim
Kysar, Jeffrey W.
Kalfa, David - Abstract:
- Abstract: The native human heart valve leaflet contains a layered microstructure comprising a hierarchical arrangement of collagen, elastin, proteoglycans and various cell types. Here, we review the various experimental methods that have been employed to probe this intricate microstructure and which attempt to elucidate the mechanisms that govern the leaflet's mechanical properties. These methods include uniaxial, biaxial, and flexural tests, coupled with microstructural characterization techniques such as small angle X-ray scattering (SAXS), small angle light scattering (SALS), and polarized light microscopy. These experiments have revealed complex elastic and viscoelastic mechanisms that are highly directional and dependent upon loading conditions and biochemistry. Of all engineering materials, polymers and polymer-based composites are best able to mimic the tissue-level mechanical behavior of the native leaflet. This similarity to native tissue permits the fabrication of polymeric valves with physiological flow patterns, reducing the risk of thrombosis compared to mechanical valves and in some cases surpassing the in vivo durability of bioprosthetic valves. Earlier work on polymeric valves simply assumed the mechanical properties of the polymer material to be linear elastic, while more recent studies have considered the full hyperelastic stress-strain response. These material models have been incorporated into computational models for the optimization of valve geometry,Abstract: The native human heart valve leaflet contains a layered microstructure comprising a hierarchical arrangement of collagen, elastin, proteoglycans and various cell types. Here, we review the various experimental methods that have been employed to probe this intricate microstructure and which attempt to elucidate the mechanisms that govern the leaflet's mechanical properties. These methods include uniaxial, biaxial, and flexural tests, coupled with microstructural characterization techniques such as small angle X-ray scattering (SAXS), small angle light scattering (SALS), and polarized light microscopy. These experiments have revealed complex elastic and viscoelastic mechanisms that are highly directional and dependent upon loading conditions and biochemistry. Of all engineering materials, polymers and polymer-based composites are best able to mimic the tissue-level mechanical behavior of the native leaflet. This similarity to native tissue permits the fabrication of polymeric valves with physiological flow patterns, reducing the risk of thrombosis compared to mechanical valves and in some cases surpassing the in vivo durability of bioprosthetic valves. Earlier work on polymeric valves simply assumed the mechanical properties of the polymer material to be linear elastic, while more recent studies have considered the full hyperelastic stress-strain response. These material models have been incorporated into computational models for the optimization of valve geometry, with the goal of minimizing internal stresses and improving durability. The latter portion of this review recounts these developments in polymeric heart valves, with a focus on mechanical testing of polymers, valve geometry, and manufacturing methods. … (more)
- Is Part Of:
- Biomaterials. Volume 225(2019)
- Journal:
- Biomaterials
- Issue:
- Volume 225(2019)
- Issue Display:
- Volume 225, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 225
- Issue:
- 2019
- Issue Sort Value:
- 2019-0225-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- Native heart valves -- Polymeric heart valves -- Soft tissue mechanics -- Mechanobiology -- Mechanical testing
Biomedical materials -- Periodicals
Biocompatible Materials -- Periodicals
Biomatériaux -- Périodiques
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01429612 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01429612 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01429612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biomaterials.2019.119493 ↗
- Languages:
- English
- ISSNs:
- 0142-9612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.715000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11903.xml