Liver phantom design and dosimetric verification in participating institutions for a proton beam therapy in patients with resectable hepatocellular carcinoma: Japan Clinical Oncology Group trial (JCOG1315C). (November 2019)
- Record Type:
- Journal Article
- Title:
- Liver phantom design and dosimetric verification in participating institutions for a proton beam therapy in patients with resectable hepatocellular carcinoma: Japan Clinical Oncology Group trial (JCOG1315C). (November 2019)
- Main Title:
- Liver phantom design and dosimetric verification in participating institutions for a proton beam therapy in patients with resectable hepatocellular carcinoma: Japan Clinical Oncology Group trial (JCOG1315C)
- Authors:
- Nishio, Teiji
Tachibana, Hidenobu
Kase, Yuki
Hotta, Kenji
Nakamura, Mitsuhiro
Tamura, Masaya
Terunuma, Toshiyuki
Toshito, Toshiyuki
Yamashita, Haruo
Ishikura, Satoshi
Fuji, Hiroshi
Akimoto, Tetsuo
Nishimura, Yasumasa - Abstract:
- Highlights: The water tank-type liver phantom for proton therapy in the JCOG trial was designed. This audit targeted the proton therapy system of three vendors at five institutions. The difference between calculated and measured dose was within 3% for all systems. Abstract: Background and purpose: In Japan, the first domestic clinical trial of proton beam therapy for the liver was initiated as the Japan Clinical Oncology Group trial (JCOG1315C: Non-randomized controlled study comparing proton beam therapy and hepatectomy for resectable hepatocellular carcinoma). Purposes of this study were to develop a new dosimetric verification system and to carry out a credentialing for the JCOG1315C clinical trial. Materials and methods: Accuracy and differences in doses in proton treatment planning among participating institutions were surveyed and investigated. We designed and developed a suitable water tank-type liver phantom for a dosimetric verification of proton beam therapy for liver. In a visiting survey of five institutions participating in the clinical trial, we performed the dosimetric verification using the liver phantom and an air-filled ionization chamber. Results: The shape of the dose distributions calculated in proton treatment planning was characteristic and dependent on the manufacturers of the proton beam therapy system, the proton treatment planning system and the setup at the participating institutions. Widths of the lateral penumbra were 5.8–12.7 mm amongHighlights: The water tank-type liver phantom for proton therapy in the JCOG trial was designed. This audit targeted the proton therapy system of three vendors at five institutions. The difference between calculated and measured dose was within 3% for all systems. Abstract: Background and purpose: In Japan, the first domestic clinical trial of proton beam therapy for the liver was initiated as the Japan Clinical Oncology Group trial (JCOG1315C: Non-randomized controlled study comparing proton beam therapy and hepatectomy for resectable hepatocellular carcinoma). Purposes of this study were to develop a new dosimetric verification system and to carry out a credentialing for the JCOG1315C clinical trial. Materials and methods: Accuracy and differences in doses in proton treatment planning among participating institutions were surveyed and investigated. We designed and developed a suitable water tank-type liver phantom for a dosimetric verification of proton beam therapy for liver. In a visiting survey of five institutions participating in the clinical trial, we performed the dosimetric verification using the liver phantom and an air-filled ionization chamber. Results: The shape of the dose distributions calculated in proton treatment planning was characteristic and dependent on the manufacturers of the proton beam therapy system, the proton treatment planning system and the setup at the participating institutions. Widths of the lateral penumbra were 5.8–12.7 mm among participating institutions. The accuracy between the calculated and the measured doses in the proton irradiation was within 3% at five measurement points including both points on the isocenter and off the isocenter. Conclusions: These findings confirmed the accuracy of the delivery doses in the institutions participating in the clinical trial, and the clinical trial with integration of all institutions (five institutions) could be initiated. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 140(2019)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 140(2019)
- Issue Display:
- Volume 140, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 140
- Issue:
- 2019
- Issue Sort Value:
- 2019-0140-2019-0000
- Page Start:
- 98
- Page End:
- 104
- Publication Date:
- 2019-11
- Subjects:
- Dosimetric verification -- Water tank-type liver phantom -- Liver proton therapy clinical trial
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2019.06.005 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11889.xml