Experimental study on the impact of facade design on indoor thermal environment in tropical residential buildings. (December 2019)
- Record Type:
- Journal Article
- Title:
- Experimental study on the impact of facade design on indoor thermal environment in tropical residential buildings. (December 2019)
- Main Title:
- Experimental study on the impact of facade design on indoor thermal environment in tropical residential buildings
- Authors:
- Tong, Shanshan
Wong, Nyuk Hien
Tan, Erna
Jusuf, Steve Kardinal - Abstract:
- Abstract: This paper presents an experimental study on the indoor air temperature near residential facades in naturally ventilated buildings in tropical climate of Singapore. Four residential sites (Site A-D) with different design features were selected for investigation. Indoor measurements were conducted at locations 30-cm away from the façades. Field measurement results showed that windows are of great significance to indoor thermal environment. In vacant units, the peak indoor air temperature reached 44 °C near a large west-facing window at Site A on sunny afternoon, when windows were kept closed and window-to-wall ratio (WWR) was 0.9. Air temperature near the closed window was lowered by 4.1 °C in the afternoon when WWR was reduced from 0.9 to 0.6. Moreover, window openings can effectively lower the indoor air temperature. At Site B, indoor air near a closed window was 7.6 °C hotter than that near an open window with the same orientation and window, and the average temperature difference reached 3.2 °C during daytime (7:00–19:00). In occupied units, air temperature near the north-facing façade was found 4.7 °C higher than that near the east-facing façade in July at Site D, due the sun path in Singapore. The percentages of time with indoor comfortable conditions were evaluated using the criterion for Asian residential buildings in summer. It was found that the acceptable time percentages were no less than 80% for indoor locations with daytime or occasional windowAbstract: This paper presents an experimental study on the indoor air temperature near residential facades in naturally ventilated buildings in tropical climate of Singapore. Four residential sites (Site A-D) with different design features were selected for investigation. Indoor measurements were conducted at locations 30-cm away from the façades. Field measurement results showed that windows are of great significance to indoor thermal environment. In vacant units, the peak indoor air temperature reached 44 °C near a large west-facing window at Site A on sunny afternoon, when windows were kept closed and window-to-wall ratio (WWR) was 0.9. Air temperature near the closed window was lowered by 4.1 °C in the afternoon when WWR was reduced from 0.9 to 0.6. Moreover, window openings can effectively lower the indoor air temperature. At Site B, indoor air near a closed window was 7.6 °C hotter than that near an open window with the same orientation and window, and the average temperature difference reached 3.2 °C during daytime (7:00–19:00). In occupied units, air temperature near the north-facing façade was found 4.7 °C higher than that near the east-facing façade in July at Site D, due the sun path in Singapore. The percentages of time with indoor comfortable conditions were evaluated using the criterion for Asian residential buildings in summer. It was found that the acceptable time percentages were no less than 80% for indoor locations with daytime or occasional window ventilation. Façade design recommendations were proposed to reduce indoor air temperature and improve indoor thermal comfort in tropical climate. Highlights: Both vacant and occupied residential buildings in tropics were studied. Indoor air temperature near different residential facades were measured. The impact of façade orientation, WWR, external shading, and openings was evaluated. Residential façade design recommendations are provided for indoor thermal comfort. … (more)
- Is Part Of:
- Building and environment. Volume 166(2019)
- Journal:
- Building and environment
- Issue:
- Volume 166(2019)
- Issue Display:
- Volume 166, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 166
- Issue:
- 2019
- Issue Sort Value:
- 2019-0166-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- Residential façade design -- Tropical climate -- Natural ventilated buildings -- Indoor air temperature
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2019.106418 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11898.xml