Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves. Issue 10 (3rd July 2019)
- Record Type:
- Journal Article
- Title:
- Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves. Issue 10 (3rd July 2019)
- Main Title:
- Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves
- Authors:
- Mao, Jifu
Rassoli, Aisa
Tong, Yiwei
Rouse, Elizabeth Nicole
Le‐Bel, Gaёtan
How, Daniel
Germain, Lucie
Fatouraee, Nasser
Zhang, Ze
Reed, Robert R.
Guidoin, Robert - Abstract:
- Abstract: Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open‐heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long‐term serviceability of the pericardium tissue from which the leaflets are made. The collagen architecture, wall thickness and mechanical properties of donkey pericardium were investigated to assess its suitability as an alternative material for the manufacture of heart valves. Coupons sampled from different locations of donkey pericardium were investigated. Bovine, equine, and porcine pericardium specimens served as controls. The donkey pericardium had a similar surface morphology to that of the control pericardia except for the wavy topology on both the fibrous and serous sides. The average thickness of donkey pericardium (ca. 120 µm) was significantly lower than that from bovine (375 µm) and equine (410 µm), but slightly higher than that from porcine (99 µm) specimens. The interlaced wavy collagen bundles in the pericardium were composed of collagen fibers about 100 nm in diameter. This unique structure ensures that the donkey pericardium has a comparable ultimate tensile strength (UTS) and a much higher failure strain than the commercial pericardia used for the manufacture of heart valves. The donkey pericardium has an organized wavy collagen bundle architectureAbstract: Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open‐heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long‐term serviceability of the pericardium tissue from which the leaflets are made. The collagen architecture, wall thickness and mechanical properties of donkey pericardium were investigated to assess its suitability as an alternative material for the manufacture of heart valves. Coupons sampled from different locations of donkey pericardium were investigated. Bovine, equine, and porcine pericardium specimens served as controls. The donkey pericardium had a similar surface morphology to that of the control pericardia except for the wavy topology on both the fibrous and serous sides. The average thickness of donkey pericardium (ca. 120 µm) was significantly lower than that from bovine (375 µm) and equine (410 µm), but slightly higher than that from porcine (99 µm) specimens. The interlaced wavy collagen bundles in the pericardium were composed of collagen fibers about 100 nm in diameter. This unique structure ensures that the donkey pericardium has a comparable ultimate tensile strength (UTS) and a much higher failure strain than the commercial pericardia used for the manufacture of heart valves. The donkey pericardium has an organized wavy collagen bundle architecture similar to that of bovine pericardium and has a satisfactory UTS and high failure strain. The thin and strong donkey pericardium might be a good candidate valve leaflet material for TAVI. … (more)
- Is Part Of:
- Artificial organs. Volume 43:Issue 10(2019)
- Journal:
- Artificial organs
- Issue:
- Volume 43:Issue 10(2019)
- Issue Display:
- Volume 43, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2019-0043-0010-0000
- Page Start:
- 976
- Page End:
- 987
- Publication Date:
- 2019-07-03
- Subjects:
- collagen architecture -- donkey pericardium -- tissue thickness -- transcatheter heart valve
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.13503 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: