Discrepancy in Doppler waveforms between two umbilical arteries in fetuses with absent or reversed end‐diastolic flow: A prospective observational study. Issue 9 (24th August 2019)
- Record Type:
- Journal Article
- Title:
- Discrepancy in Doppler waveforms between two umbilical arteries in fetuses with absent or reversed end‐diastolic flow: A prospective observational study. Issue 9 (24th August 2019)
- Main Title:
- Discrepancy in Doppler waveforms between two umbilical arteries in fetuses with absent or reversed end‐diastolic flow: A prospective observational study
- Authors:
- Park, Jeong W.
Lee, Seung M.
Kang, Hye‐S.
Shim, Soon‐S.
Jun, Jong K. - Abstract:
- Abstract: Purpose: To asses the occurrence of discrepancies between the Doppler waveforms of the left and right umbilical arteries in their paravesical part in fetuses with absent or reversed end‐diastolic flow in the free‐floating umbilical cord. Methods: This prospective observational study included pregnant women with fetal growth restriction or twin‐to‐twin transfusion syndrome. Umbilical arterial Doppler waveforms were obtained from both umbilical arteries in their intra‐abdominal paravesical part. Doppler findings were recorded as present end‐diastolic flow (PEDF)/absent end‐diastolic flow (AEDF); AEDF/AEDF; AEDF/reversed end‐diastolic flow (REDF); or REDF/REDF pattern. Results: There were 49 fetuses with AEDF or REDF at the free‐floating umbilical cord. Of these, 20 (40.8%) had a discrepancy in Doppler waveforms between the two umbilical arteries, with 14 (28.6%) showing PEDF/AEDF, 17 (34.7%) AEDF/AEDF, 6 (12.2%) AEDF/REDF, and 12 (24.5%) REDF/REDF pattern. Conclusion: Doppler waveforms showed discrepancies between the two umbilical arteries in 40.8% of pregnant women with AEDF or REDF in the free‐floating umbilical cord. The presence of end‐diastolic flow in one umbilical artery cannot exclude the possibility of AEDF in the other.
- Is Part Of:
- Journal of clinical ultrasound. Volume 47:Issue 9(2019)
- Journal:
- Journal of clinical ultrasound
- Issue:
- Volume 47:Issue 9(2019)
- Issue Display:
- Volume 47, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 9
- Issue Sort Value:
- 2019-0047-0009-0000
- Page Start:
- 526
- Page End:
- 530
- Publication Date:
- 2019-08-24
- Subjects:
- absent end‐diastolic flow -- Doppler velocimetry -- reversed end‐diastolic flow -- umbilical artery
Ultrasonics in medicine -- Periodicals
616.07543 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcu.22770 ↗
- Languages:
- English
- ISSNs:
- 0091-2751
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.791000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11900.xml