Monitoring bioactive and total antibody concentrations for continuous process control by surface plasmon resonance spectroscopy. Issue 10 (20th August 2019)
- Record Type:
- Journal Article
- Title:
- Monitoring bioactive and total antibody concentrations for continuous process control by surface plasmon resonance spectroscopy. Issue 10 (20th August 2019)
- Main Title:
- Monitoring bioactive and total antibody concentrations for continuous process control by surface plasmon resonance spectroscopy
- Authors:
- Zschätzsch, Marlen
Ritter, Paul
Henseleit, Anja
Wiehler, Klaus
Malik, Sven
Bley, Thomas
Walther, Thomas
Boschke, Elke - Abstract:
- Abstract: Monoclonal antibodies have become an increasingly important part of fundamental research and medical applications. To meet the high market demand for monoclonal antibodies in the biopharmaceutical sector, industrial manufacturing needs to be achieved by large scale, highly productive and consistent production processes. These are subject to international guidelines and have to be monitored intensely due to high safety standards for medical applications. Surface plasmon resonance spectroscopy — a fast, real‐time, and label‐free bio‐sensing method — represents an interesting alternative to the quantification of monoclonal antibody concentrations by enzyme‐linked immunosorbent assay during monoclonal antibody production. For the application of monitoring bioactive and total monoclonal antibody concentrations in cell culture samples, a surface plasmon resonance assay using a target‐monoclonal antibody model system was developed. In order to ensure the subsequent detection of bioactive monoclonal antibody concentrations, suitable immobilization strategies of the target were identified. A significant decrease of the limit of detection was achieved by using an adapted affinity method compared to the commonly used amine coupling. Furthermore, the system showed limit of detection in the low ng/mL range similar to control quantifications by enzyme‐linked immunosorbent assay. Moreover, the comparison of total to bioactive monoclonal antibody concentrations allows analysis ofAbstract: Monoclonal antibodies have become an increasingly important part of fundamental research and medical applications. To meet the high market demand for monoclonal antibodies in the biopharmaceutical sector, industrial manufacturing needs to be achieved by large scale, highly productive and consistent production processes. These are subject to international guidelines and have to be monitored intensely due to high safety standards for medical applications. Surface plasmon resonance spectroscopy — a fast, real‐time, and label‐free bio‐sensing method — represents an interesting alternative to the quantification of monoclonal antibody concentrations by enzyme‐linked immunosorbent assay during monoclonal antibody production. For the application of monitoring bioactive and total monoclonal antibody concentrations in cell culture samples, a surface plasmon resonance assay using a target‐monoclonal antibody model system was developed. In order to ensure the subsequent detection of bioactive monoclonal antibody concentrations, suitable immobilization strategies of the target were identified. A significant decrease of the limit of detection was achieved by using an adapted affinity method compared to the commonly used amine coupling. Furthermore, the system showed limit of detection in the low ng/mL range similar to control quantifications by enzyme‐linked immunosorbent assay. Moreover, the comparison of total to bioactive monoclonal antibody concentrations allows analysis of antibody production efficiency. The development of an alternative quantification system to monitor monoclonal antibody production was accomplished using surface plasmon resonance with the advantage of low analyte volume, shorter assay time, and biosensor reusability by target‐layer regeneration. The established method provides the basis for the technical development of a surface plasmon resonance‐based system for continuous process monitoring. … (more)
- Is Part Of:
- Engineering in life sciences. Volume 19:Issue 10(2019)
- Journal:
- Engineering in life sciences
- Issue:
- Volume 19:Issue 10(2019)
- Issue Display:
- Volume 19, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 19
- Issue:
- 10
- Issue Sort Value:
- 2019-0019-0010-0000
- Page Start:
- 681
- Page End:
- 690
- Publication Date:
- 2019-08-20
- Subjects:
- antibody -- bioactive and total antibody concentration -- monitoring -- surface plasmon resonance
Bioengineering -- Periodicals
660.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1618-2863 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elsc.201900014 ↗
- Languages:
- English
- ISSNs:
- 1618-0240
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3764.680000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11879.xml