Mitigating the open vessel artefact in centrifuge-based measurement of embolism resistance. (1st August 2018)
- Record Type:
- Journal Article
- Title:
- Mitigating the open vessel artefact in centrifuge-based measurement of embolism resistance. (1st August 2018)
- Main Title:
- Mitigating the open vessel artefact in centrifuge-based measurement of embolism resistance
- Authors:
- López, Rosana
Nolf, Markus
Duursma, Remko A
Badel, Eric
Flavel, Richard J
Cochard, Hervé
Choat, Brendan - Editors:
- Tognetti, Roberto
- Abstract:
- Abstract: Centrifuge-based techniques to assess xylem vulnerability to embolism are increasingly being used, although we are yet to reach a consensus on the nature and extent of artefactual embolism observed in some angiosperm species. In particular, there is disagreement over whether these artefacts influence both the spin (Cavitron) and static versions of the centrifuge technique equally. We tested two methods for inducing embolism: bench dehydration and centrifugation. We used three methods to measure the resulting loss of conductivity: gravimetric flow measured in bench-dehydrated and centrifuged samples (static centrifuge), in situ flow measured under tension during spinning in the centrifuge (Cavitron) and direct imaging using X-ray computed microtomography (microCT) observations in stems of two species of Hakea that differ in vessel length. Both centrifuge techniques were prone to artefactual embolism in samples with maximum vessel length longer than, or similar to, the centrifuge rotor diameter. Observations with microCT indicated that this artefactual embolism occurred in the outermost portions of samples. The artefact was largely eliminated if flow was measured in an excised central part of the segment in the static centrifuge or starting measurements with the Cavitron at pressures lower than the threshold of embolism formation in open vessels. The simulations of loss of conductivity in centrifuged samples with a new model, CAVITOPEN, confirmed that the impact ofAbstract: Centrifuge-based techniques to assess xylem vulnerability to embolism are increasingly being used, although we are yet to reach a consensus on the nature and extent of artefactual embolism observed in some angiosperm species. In particular, there is disagreement over whether these artefacts influence both the spin (Cavitron) and static versions of the centrifuge technique equally. We tested two methods for inducing embolism: bench dehydration and centrifugation. We used three methods to measure the resulting loss of conductivity: gravimetric flow measured in bench-dehydrated and centrifuged samples (static centrifuge), in situ flow measured under tension during spinning in the centrifuge (Cavitron) and direct imaging using X-ray computed microtomography (microCT) observations in stems of two species of Hakea that differ in vessel length. Both centrifuge techniques were prone to artefactual embolism in samples with maximum vessel length longer than, or similar to, the centrifuge rotor diameter. Observations with microCT indicated that this artefactual embolism occurred in the outermost portions of samples. The artefact was largely eliminated if flow was measured in an excised central part of the segment in the static centrifuge or starting measurements with the Cavitron at pressures lower than the threshold of embolism formation in open vessels. The simulations of loss of conductivity in centrifuged samples with a new model, CAVITOPEN, confirmed that the impact of open vessels on the vulnerability to embolism curve was higher when vessels were long, samples short and when embolism is formed in open vessels at less negative pressures. This model also offers a robust and quantitative tool to test and correct for artefactual embolism at low xylem tensions. … (more)
- Is Part Of:
- Tree physiology. Volume 39:Number 1(2019)
- Journal:
- Tree physiology
- Issue:
- Volume 39:Number 1(2019)
- Issue Display:
- Volume 39, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2019-0039-0001-0000
- Page Start:
- 143
- Page End:
- 155
- Publication Date:
- 2018-08-01
- Subjects:
- CAVITOPEN -- Cavitron -- centrifuge technique -- drought -- vulnerability to embolism -- X-ray microCT -- xylem embolism
Trees -- Physiology -- Periodicals
582.16 - Journal URLs:
- http://treephys.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/treephys/tpy083 ↗
- Languages:
- English
- ISSNs:
- 0829-318X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9047.625000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11873.xml