Application of simple and sensitive LC‐MS/MS approach for trace level quantification of potential genotoxic impurities in lamivudine salicylate formulations. Issue 10 (10th September 2019)
- Record Type:
- Journal Article
- Title:
- Application of simple and sensitive LC‐MS/MS approach for trace level quantification of potential genotoxic impurities in lamivudine salicylate formulations. Issue 10 (10th September 2019)
- Main Title:
- Application of simple and sensitive LC‐MS/MS approach for trace level quantification of potential genotoxic impurities in lamivudine salicylate formulations
- Authors:
- Ganji, Sreenivasula Rao
Gopireddy, Venkata Subba Reddy - Abstract:
- Abstract: A new liquid chromatography with tandem mass spectrometry systematic procedure was envisaged for determination of l‐menthol glyoxylate and (1R, 2S, 5R)‐menthyl‐5(R, S)‐acetoxy‐(1, 3)‐oxathiolane‐2(R)‐carboxylate, the potential genotoxic impurities in lamivudine salicylate drug formulation. The process describes an effective use of Hypersil BDS C8 (50 mm × 4.6 mm, 3.0 µm) column retained at 40°C and positive ion electrospray ionization in multiple reaction‐monitoring mode for quantification of two genotoxic impurities. The mobile phase comprises of 60:40 ratio of 5 mM ammonium formate and combination of acetonitrile/methanol (50:50 v/v) pumped at the flow rate of 0.5 mL/min with run time 10 min. This approach was validated for robustness, reproducibility, precision, linearity, accuracy, limit of detection and limit of quantification by following ICH guidelines. The established approach is able to assess two genotoxic impurities at 0.3 ppm (LOQ) against to 2.0 mg/mL of lamivudine. The linearity of this approach is found to 0.3–10.0 ppm, which meets the quantified accepted level (5.0 ppm) in LOQ‐200% range with the correlation coefficients of 0.999 and 0.997. Accuracy was arrived between 98.7–103.1%. The validated method could be highly useful as a good quality assessment tool for quantitation of genotoxic impurities in lamivudine formulation.
- Is Part Of:
- Separation science plus. Volume 2:Issue 10(2019)
- Journal:
- Separation science plus
- Issue:
- Volume 2:Issue 10(2019)
- Issue Display:
- Volume 2, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 2
- Issue:
- 10
- Issue Sort Value:
- 2019-0002-0010-0000
- Page Start:
- 375
- Page End:
- 383
- Publication Date:
- 2019-09-10
- Subjects:
- genotoxic impurities -- lamivudine salicylate -- method development -- validation
Chromatographic analysis -- Periodicals
543.8 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/25731815 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/sscp.201900032 ↗
- Languages:
- English
- ISSNs:
- 2573-1815
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8242.256500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11862.xml