A methodological approach for the simultaneous quantification of glycerol and fatty acids from cork suberin in a single GC run. Issue 6 (19th June 2019)
- Record Type:
- Journal Article
- Title:
- A methodological approach for the simultaneous quantification of glycerol and fatty acids from cork suberin in a single GC run. Issue 6 (19th June 2019)
- Main Title:
- A methodological approach for the simultaneous quantification of glycerol and fatty acids from cork suberin in a single GC run
- Authors:
- Marques, António V.
Pereira, Helena - Abstract:
- Abstract: Introduction: Suberin, as part of plant protective barriers, is one of the most important natural polymers after cellulose and lignin. For a full elucidation of suberin structure the quantification of glycerol, fatty α, ω‐diacids and ω‐hydroxyacids, the major building blocks of suberin, is of primary importance. Glycerol is often lost in the most used analytical procedures or rarely determined by deficient or too laborious techniques. Objectives: Propose a simple, accessible and reliable methanolysis work‐up procedure for an accurate and simultaneous quantification of glycerol and suberin fatty monomers in the same GC run. Material and methods: Cork from Quercus suber L. was depolymerised by methanolysis. Glycerol was derivatised to an organic soluble form before the suberin monomers recovery in water/organic solvent partition. Gas chromatography flame ionisation detector (GC‐FID) response factors were determined for glycerol, ferulic acid and one for each fatty monomer substructure. Additionally, 1, 2, 4‐butanetriol and methyl nonadecanoate were used as internal standards. Results: The proposed experimental approach allowed the glycerol and all the fatty suberin monomers in the same GC run to be quantified accurately. Glycerol represented 30.6 area%, 14.2 mass% and 38.4 molar% of suberin and the COOH/OH groups ratio was 0.6:1 in the proposed experimental approach in contrast with 0.10 area% and COOH/OH ratio of 3:1 in the most used protocol. Furthermore,Abstract: Introduction: Suberin, as part of plant protective barriers, is one of the most important natural polymers after cellulose and lignin. For a full elucidation of suberin structure the quantification of glycerol, fatty α, ω‐diacids and ω‐hydroxyacids, the major building blocks of suberin, is of primary importance. Glycerol is often lost in the most used analytical procedures or rarely determined by deficient or too laborious techniques. Objectives: Propose a simple, accessible and reliable methanolysis work‐up procedure for an accurate and simultaneous quantification of glycerol and suberin fatty monomers in the same GC run. Material and methods: Cork from Quercus suber L. was depolymerised by methanolysis. Glycerol was derivatised to an organic soluble form before the suberin monomers recovery in water/organic solvent partition. Gas chromatography flame ionisation detector (GC‐FID) response factors were determined for glycerol, ferulic acid and one for each fatty monomer substructure. Additionally, 1, 2, 4‐butanetriol and methyl nonadecanoate were used as internal standards. Results: The proposed experimental approach allowed the glycerol and all the fatty suberin monomers in the same GC run to be quantified accurately. Glycerol represented 30.6 area%, 14.2 mass% and 38.4 molar% of suberin and the COOH/OH groups ratio was 0.6:1 in the proposed experimental approach in contrast with 0.10 area% and COOH/OH ratio of 3:1 in the most used protocol. Furthermore, ω‐hydroxyacids/α, ω‐diacids mass ratio was 1:1 as opposed to an area ratio of 1.5:1. Conclusion: The proposed work‐up procedure revealed to be a reliable analytical tool for the complete analysis of suberin allowing the future knowledge to grow towards a better understanding of suberin structure throughout its range and variability. Abstract : In the present work an alternative methanolysis work‐up methodology was developed for the isolation of depolymerized suberin in order to quantify accurately all suberin building blocks, including glycerol, in the same GC run. GC‐FID response factors were determined for glycerol and each suberin fatty acid substructure with internal standards. Glycerol represented 38.4 molar% of suberin and COOH/OH groups ratio was 0.6:1 in contrast with 0.10 area% and COOH/OH ratio of 3:1 in the most used methanolysis methodology. … (more)
- Is Part Of:
- Phytochemical analysis. Volume 30:Issue 6(2019)
- Journal:
- Phytochemical analysis
- Issue:
- Volume 30:Issue 6(2019)
- Issue Display:
- Volume 30, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2019-0030-0006-0000
- Page Start:
- 687
- Page End:
- 699
- Publication Date:
- 2019-06-19
- Subjects:
- cork -- GC‐FID -- glycerol -- response factors -- suberin
Plants -- Analysis -- Periodicals
Plants -- chemistry -- Periodicals
572.2 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/pca.2846 ↗
- Languages:
- English
- ISSNs:
- 0958-0344
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6489.695000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11864.xml