Comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA: can one tracer replace the other?. (3rd October 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA: can one tracer replace the other?. (3rd October 2019)
- Main Title:
- Comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA: can one tracer replace the other?
- Authors:
- Andersen, Trine B.
Jødal, Lars
Nielsen, Nikolaj S.
Petersen, Lars J. - Abstract:
- Abstract: Both 99m Tc-DTPA and 51 Cr-EDTA are widely used to determine glomerular filtration rate (GFR), but few direct comparative studies exist. The shortage of 51 Cr-EDTA makes a direct comparison highly relevant. The aim of the study was to investigate if there is any clinically relevant difference between plasma clearance of 99m Tc-DTPA and 51 Cr-EDTA. Patients ≥18 years of age referred for routine GFR measurement by 51 Cr-EDTA were prospectively enrolled. The two tracers (10 MBq 99m Tc-DTPA (CaNa3 -DTPA) and 2.5 MBq 51 Cr-EDTA) were intravenously injected at time zero. A standard 4-sample technique was applied with samples collected at 180, 200, 220 and 240 min, if the estimated GFR (eGFR) was ≥30 mL/min. A comparison of single-sample GFR based on the 200 min sample was also conducted. Fifty-six patients were enrolled in the study. All patients had an estimated GFR >30 mL/min/1.73 m 2 . No patients suffered from ascites or significant oedema. The mean 51 Cr-EDTA plasma clearance was 82 mL/min (range 16–226). The plasma clearances determined by the two methods were highly correlated ( r = 0.993). The plasma clearance was significantly higher when measured by 99m Tc-DTPA than by 51 Cr-EDTA ( p = 0.01), but the numerical difference was minimal (mean difference 1.4 mL/min; 95% limits of agreement (LOA) –6.6 to 9.4). The difference between the two methods was independent of the level of renal function. Similar results were found for one-sample GFR. No clinically relevantAbstract: Both 99m Tc-DTPA and 51 Cr-EDTA are widely used to determine glomerular filtration rate (GFR), but few direct comparative studies exist. The shortage of 51 Cr-EDTA makes a direct comparison highly relevant. The aim of the study was to investigate if there is any clinically relevant difference between plasma clearance of 99m Tc-DTPA and 51 Cr-EDTA. Patients ≥18 years of age referred for routine GFR measurement by 51 Cr-EDTA were prospectively enrolled. The two tracers (10 MBq 99m Tc-DTPA (CaNa3 -DTPA) and 2.5 MBq 51 Cr-EDTA) were intravenously injected at time zero. A standard 4-sample technique was applied with samples collected at 180, 200, 220 and 240 min, if the estimated GFR (eGFR) was ≥30 mL/min. A comparison of single-sample GFR based on the 200 min sample was also conducted. Fifty-six patients were enrolled in the study. All patients had an estimated GFR >30 mL/min/1.73 m 2 . No patients suffered from ascites or significant oedema. The mean 51 Cr-EDTA plasma clearance was 82 mL/min (range 16–226). The plasma clearances determined by the two methods were highly correlated ( r = 0.993). The plasma clearance was significantly higher when measured by 99m Tc-DTPA than by 51 Cr-EDTA ( p = 0.01), but the numerical difference was minimal (mean difference 1.4 mL/min; 95% limits of agreement (LOA) –6.6 to 9.4). The difference between the two methods was independent of the level of renal function. Similar results were found for one-sample GFR. No clinically relevant differences were found between the plasma clearance of 99m Tc-DTPA and that of 51 Cr-EDTA. Therefore, 99m Tc-DTPA can replace 51 Cr-EDTA when needed. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 79:Number 7(2019)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 79:Number 7(2019)
- Issue Display:
- Volume 79, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 79
- Issue:
- 7
- Issue Sort Value:
- 2019-0079-0007-0000
- Page Start:
- 463
- Page End:
- 467
- Publication Date:
- 2019-10-03
- Subjects:
- GFR -- renal function -- 51Cr-EDTA -- 99mTcDTPA -- glomerular filtration rate -- plasma clearance
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2019.1658217 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11862.xml