High‐fidelity, high‐isotropic‐resolution diffusion imaging through gSlider acquisition with B1+ and T1 corrections and integrated ΔB0/Rx shim array. Issue 1 (1st August 2019)
- Record Type:
- Journal Article
- Title:
- High‐fidelity, high‐isotropic‐resolution diffusion imaging through gSlider acquisition with B1+ and T1 corrections and integrated ΔB0/Rx shim array. Issue 1 (1st August 2019)
- Main Title:
- High‐fidelity, high‐isotropic‐resolution diffusion imaging through gSlider acquisition with B1+ and T1 corrections and integrated ΔB0/Rx shim array
- Authors:
- Liao, Congyu
Stockmann, Jason
Tian, Qiyuan
Bilgic, Berkin
Arango, Nicolas S.
Manhard, Mary Kate
Huang, Susie Y.
Grissom, William A.
Wald, Lawrence L.
Setsompop, Kawin - Abstract:
- Abstract : Purpose: B 1 + and T 1 corrections and dynamic multicoil shimming approaches were proposed to improve the fidelity of high‐isotropic‐resolution generalized slice‐dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B 1 + inhomogeneity and T 1 recovery information was developed to mitigate slab‐boundary artifacts in short‐repetition time (TR) gSlider acquisitions. Slab‐by‐slab dynamic B 0 shimming using a multicoil integrated Δ B 0 / Rx shim array and high in‐plane acceleration ( R inplane = 4) achieved with virtual‐coil GRAPPA were also incorporated into a 1‐mm isotropic resolution gSlider acquisition/reconstruction framework to achieve a significant reduction in geometric distortion compared to single‐shot echo planar imaging (EPI). Results: The slab‐boundary artifacts were alleviated by the proposed B 1 + and T 1 corrections compared to the standard gSlider reconstruction pipeline for short‐TR acquisitions. Dynamic shimming provided >50% reduction in geometric distortion compared to conventional global second‐order shimming. One‐millimeter isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high geometric fidelity using dynamic shimming. Conclusions: The proposed B 1 + and T 1 corrections and local‐field control substantially improved the fidelity of high‐isotropic‐resolution diffusion imaging, with reduced slab‐boundary artifactsAbstract : Purpose: B 1 + and T 1 corrections and dynamic multicoil shimming approaches were proposed to improve the fidelity of high‐isotropic‐resolution generalized slice‐dithered enhanced resolution (gSlider) diffusion imaging. Methods: An extended reconstruction incorporating B 1 + inhomogeneity and T 1 recovery information was developed to mitigate slab‐boundary artifacts in short‐repetition time (TR) gSlider acquisitions. Slab‐by‐slab dynamic B 0 shimming using a multicoil integrated Δ B 0 / Rx shim array and high in‐plane acceleration ( R inplane = 4) achieved with virtual‐coil GRAPPA were also incorporated into a 1‐mm isotropic resolution gSlider acquisition/reconstruction framework to achieve a significant reduction in geometric distortion compared to single‐shot echo planar imaging (EPI). Results: The slab‐boundary artifacts were alleviated by the proposed B 1 + and T 1 corrections compared to the standard gSlider reconstruction pipeline for short‐TR acquisitions. Dynamic shimming provided >50% reduction in geometric distortion compared to conventional global second‐order shimming. One‐millimeter isotropic resolution diffusion data show that the typically problematic temporal and frontal lobes of the brain can be imaged with high geometric fidelity using dynamic shimming. Conclusions: The proposed B 1 + and T 1 corrections and local‐field control substantially improved the fidelity of high‐isotropic‐resolution diffusion imaging, with reduced slab‐boundary artifacts and geometric distortion compared to conventional gSlider acquisition and reconstruction. This enabled high‐fidelity whole‐brain 1‐mm isotropic diffusion imaging with 64 diffusion directions in 20 min using a 3T clinical scanner. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 1(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 1(2020)
- Issue Display:
- Volume 83, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 1
- Issue Sort Value:
- 2020-0083-0001-0000
- Page Start:
- 56
- Page End:
- 67
- Publication Date:
- 2019-08-01
- Subjects:
- B1+inhomogeneity -- diffusion‐weighted imaging -- gSlider -- shim array
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27899 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11852.xml