Image quality comparison between model‐based iterative reconstruction and adaptive statistical iterative reconstruction chest computed tomography in cystic fibrosis patients. Issue 5 (15th May 2019)
- Record Type:
- Journal Article
- Title:
- Image quality comparison between model‐based iterative reconstruction and adaptive statistical iterative reconstruction chest computed tomography in cystic fibrosis patients. Issue 5 (15th May 2019)
- Main Title:
- Image quality comparison between model‐based iterative reconstruction and adaptive statistical iterative reconstruction chest computed tomography in cystic fibrosis patients
- Authors:
- Lin, Sandra
Lin, Monica
Lau, Kenneth K - Abstract:
- Abstract: Introduction: Cystic fibrosis (CF) predominantly affects young adults. Accurate radiological assessment of pulmonary disease is vital for predicting exacerbations, one of the leading causes of morbidity and mortality. We evaluated the image quality of model‐based iterative reconstruction (MBIR) ultra‐low‐dose CT chest (ULD‐CT) in CF evaluation. Methods: We compared ULD‐CT with standard adaptive statistical iterative reconstruction (ASIR) low‐dose CT (LD‐CT). Subjective assessment of contrast and noise were performed for each study. Background noise, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated and compared between the CT studies. Conspicuity of major structures was assessed. These aspects of image quality were compared to determine whether ULD‐CT was superior to LD‐CT in assessment of CF. Results: The ULD‐CT achieved median effective dose of 0.073 mSv, comparable to one standard chest radiograph and significantly lower than the median LD‐CT dose of 1.22 mSv. ULD‐CT had lower subjective contrast and higher subjective noise when compared to LD‐CT. Objectively measured background noise was lower in ULD‐CT (16.33 HU vs 38.53 HU, P < 0.0001) compared to LD‐CT. ULD‐CT had higher median CNR (52.65 vs 22.09, P < 0.0001) and SNR in lung (9.08 vs 7.29, P = 0.002) compared to LD‐CT. ULD‐CT was equal to LD‐CT in identification of trachea, bronchi, pleural and pericardium. Interobserver reliability showed agreement of 80–92%.Abstract: Introduction: Cystic fibrosis (CF) predominantly affects young adults. Accurate radiological assessment of pulmonary disease is vital for predicting exacerbations, one of the leading causes of morbidity and mortality. We evaluated the image quality of model‐based iterative reconstruction (MBIR) ultra‐low‐dose CT chest (ULD‐CT) in CF evaluation. Methods: We compared ULD‐CT with standard adaptive statistical iterative reconstruction (ASIR) low‐dose CT (LD‐CT). Subjective assessment of contrast and noise were performed for each study. Background noise, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated and compared between the CT studies. Conspicuity of major structures was assessed. These aspects of image quality were compared to determine whether ULD‐CT was superior to LD‐CT in assessment of CF. Results: The ULD‐CT achieved median effective dose of 0.073 mSv, comparable to one standard chest radiograph and significantly lower than the median LD‐CT dose of 1.22 mSv. ULD‐CT had lower subjective contrast and higher subjective noise when compared to LD‐CT. Objectively measured background noise was lower in ULD‐CT (16.33 HU vs 38.53 HU, P < 0.0001) compared to LD‐CT. ULD‐CT had higher median CNR (52.65 vs 22.09, P < 0.0001) and SNR in lung (9.08 vs 7.29, P = 0.002) compared to LD‐CT. ULD‐CT was equal to LD‐CT in identification of trachea, bronchi, pleural and pericardium. Interobserver reliability showed agreement of 80–92%. Conclusions: The image quality of ULD‐CT is similar to LD‐CT, at 1/16th the dose. MBIR constructed ULD‐CT is an effective imaging modality for CF surveillance, with potential applications in other disease settings. … (more)
- Is Part Of:
- Journal of medical imaging and radiation oncology. Volume 63:Issue 5(2019:Oct.)
- Journal:
- Journal of medical imaging and radiation oncology
- Issue:
- Volume 63:Issue 5(2019:Oct.)
- Issue Display:
- Volume 63, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 63
- Issue:
- 5
- Issue Sort Value:
- 2019-0063-0005-0000
- Page Start:
- 602
- Page End:
- 609
- Publication Date:
- 2019-05-15
- Subjects:
- chest -- CT -- cystic fibrosis -- MBIR -- ultra‐low dose
Radiology, Medical -- Periodicals
Radiology, Medical -- Australasia -- Periodicals
616.0757 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1754-9485 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/1754-9485.12895 ↗
- Languages:
- English
- ISSNs:
- 1754-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.072080
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11859.xml